Permit Number: T09CM02243
Parcel: 12512080A

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T09CM02243
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/07/2011 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Provide a direct waste connection for the wash and rinse sections of the 3-compartment sinks, with an indirect connection for the sanitizing compartments only. Reference: Sections 304.0, 704.3, and 801.2.3, UPC 2006.
2. The proposed FOG (Fats, Oils, and Greases) disposal systems are considered to be engineered systems. Provide the technical documentation and the manufacturer's installation instructions for the proposed FOG disposal systems. Show a detail (i.e. a riser diagram) showing how the FOG disposal systems are to be plumbed. Reference: Sections 103.2.3, 301.1.3, 301.2, and 1015.0, UPC 2006.
04/11/2011 LEERAY HANLY ELECTRICAL-COMMERCIAL REVIEW Denied PROVIDE CUT-SHEETS AND POWER REQUIREMENTS FOR HIGHLAND TANK GREASE TRAPS.

REVISE ELECTRICAL PLAN SHEETS AS NECESSARY.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/22/2011 CPIERCE1 OUT TO CUSTOMER Completed
04/22/2011 SUE REEVES REJECT SHELF Completed