Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T09CM02243
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/08/2010 | GBONILL1 | WWM | REVIEW | Needs Review | |
08/21/2009 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
08/21/2009 | ERIC NEWCOMB | ADA | REVIEW | Passed | |
08/21/2009 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE CODE ANALYSIS FOR OCCUPANCY LOAD, BUILDING TYPE, ETC. |
08/21/2009 | ERIC NEWCOMB | ZONING HC | REVIEW | Approved | |
08/21/2009 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
08/25/2009 | ROBERT SHERRY | WATER | REVIEW | Approved | |
08/25/2009 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | Project: 3360 E Speedway Bl, T09CM02243 Kitchen Equipment. The Electrical Plans have been denied for the following; Provide Engineered drawings for electrical work as per 2005 NEC. Ray T Majuta PDS City of Tucson Elect Plan Ck 8/25/09 520-837-4988 Ray.Majuta@tucsonaz.gov |
08/25/2009 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide the listing information for the new exhaust fans and the make up air units. 2. Show that the outlet of fan EF-1 complies with the requirements of Section 506.5.5, IMC 2006. 3. Provide balancing information for the new Type I and Type II hoods. Reference: Sections 507.1 and 507.13, IMC 2006. 4. Provide information to show that the operation of the Type I hoods and the hood exhaust fans comply with Section 507.2.1.1, IMC 2006. 5. Revise the installation of the hood to provide 18" of clearance between the hood and combustible construction (note that wood studs covered by gypsum board and a sheet of stainless steel are considered combustible construction by the IMC). Reference: Section 507.9, IMC 2006. 6. Show that the roof top air-conditioning units supplying make up air for the kitchen hood are electrically interlocked to the exhaust fans. Reference: Section 508.1, IMC 2006. 7. Provide information to show that the make up air for the kitchen hood complies with Section 508.1.1, IMC 2006. |
08/25/2009 | DAVE MANN | FIRE | REVIEW | Denied | Please provide code review checklist. Exiting does not appear to meet IFC Chap 10. |
08/25/2009 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Provide a plumbing plan showing how the new trench drains fit into the existing plumbing system. |
11/02/2009 | LOREN MAKUS | ENGINEERING | REVIEW | Approved |