Permit Number: T09CM01440
Parcel: 12314138A

Address:
1730 N 1ST AV

Review Status: Completed

Review Details: SITE

Permit Number - T09CM01440
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/29/2009 DAVE MANN FIRE REVIEW Approved
06/29/2009 RBROWN1 ADA REVIEW Passed NOT A COT OWNED/OPERATED PROPERTY
06/29/2009 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: International School of Tucson - Classroom Addition
T09CM01440
Site Plan (1st Review)

TRANSMITTAL DATE: June 30, 2009

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for code full compliance for the area of expansion only.

2. Provide documentation that shows that the "EXISTING SHADE STRUCTURE" was permitted.

3. Provide documentation that shows that the "EXISTING 5'-8" PERIMETER WALL" was permitted. Based on the site plan provided it appears the wall encroaches into the property to the east. This encroachment will need to be corrected prior to approval of this site plan.

4. There is a note on the plan that states "EXISTING PLAYGOUND (PAVED FORMER PARKING AREA". Based on the last approved site plan this area was a "PROPOSED PLAYGOUND", that said remove the reference to "(PAVED FORMER PARKING AREA" from the plan.

5. D.S. 2-02.2.1.A.6 There appears to be an overhang on the proposed building. If this is the case label it as such.

6. D.S. 2-02.2.1.A.7 The proposed structure does not meet the required side street perimeter yard setback. Per LUC Section 3.2.6.5.A for a side street perimeter yard a minimum of 10'-0" is required to the north property line, 0'-0" is provided. A Design Development Option (DDO) is required. For your information there may be a required 10'-0" landscape buffer yard along the north side of the proposed structure which may require a Board of Adjustment for a Variance, see landscape comments.

7. D.S. 2-02.2.1.A.7 There is a dimension of "1'-4"" at the northeast corner of the proposed structure. This dimension appears to be a dimension to the property line but does not align with the property line, please clarify.

8. D.S. 2-02.2.1.A.7 The proposed 400 S.F. shade structure does not meet the required side street perimeter yard setback. Per LUC Section 3.2.6.5.A for a side street perimeter yard a minimum of 10'-0" is required to the north property line. As a setback dimension was not provided Zoning cannot provide a complete DDO comment as this time.

9. D.S. 2-02.2.1.A.7 The proposed 500 S.F. shade structure does not meet the required front street perimeter yard setback. Per LUC Section 3.2.6.5.A for a front street perimeter yard a 20'-0" or one and one-half (1 1/2) the height of the proposed wall (H), measured from the street property line, whichever is greater, is required to the west property line. As a setback dimension was not provided Zoning cannot provide a complete DDO comment as this time.

10. D.S. 2-02.2.1.A.12 Per D.S. 2-08.3.1 a pedestrian circulation/accessible route, sidewalk is required from the proposed structure to the existing structure. A sidewalk is required between the two (2) buildings. It is not clear what is proposed on this site plan.

11. D.S. 2-02.2.1.A.13 If applicable show any existing and/or proposed signage on the plan along with the type, size and height.

12. D.S. 2-02.2.1.A.19 Provide the right-of-way dimensions for both streets on the plan.

13. D.S. 2-02.2.1.A.28 Provide the zoning for the parcels located west of 1st Avenue.

14. D.S. 2-02.2.1.A.28 The zoning shown for the property located to the south is not correct, this should be labeled as R-2.

15. D.S. 2-02.2.1.A.31 The development designator shown is not correct, the correct development designator is 29.

16. D.S. 2-02.2.2.A.3 Based on a development designator 29 the floor area ratio (FAR) shown is not correct. Per LUC Section 3.2.3.2.B the FAR is 0.50.

17. D.S. 2-02.2.2.A.4 Zoning acknowledges that the provided bicycle parking meets the minimum required but the bicycle parking calculation is not correct. Per LUC Section 3.3.3.5 Bicycle Parking Requirements. If the calculated number of required bicycle parking spaces is less than two (2), the minimum number of required spaces is two (2). This said revised the calculation to show two (2) required, two (2) provided.

18. D.S. 2-02.2.2.A.6 Provide a building expansion calculation on the plan.

19. The allowed wall height is not correct. Per LUC Section 3.2.3.2.B the maximum building height is 30'.

20. Depending on how the above comments are addressed addition comments may be forth coming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t09cm01440

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
06/29/2009 RONALD BROWN ZONING HC SITE REVIEW Denied 1. Accessible route connection to new building may not occur through the existing building. The accessible route is required by IBC Section 1104, to connect all buildings with in a site.
2. Please provide a large scale detail of the ramp onto the new building showing all critical accessible dimensions, slopes, rails as required, accessible route connection and landing.
3. Is the ramp at the back of the existing building new? If so, then ditto comment 2 above.
4. Zoning may require accessible route connection from the existing building to the new building to be concrete. Reference zoning comments.

END OF COMMENTS
07/06/2009 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: July 7, 2009
SUBJECT: Site Plan for Classroom Addition
TO: Catherine Rex
LOCATION: 1730 N 1st Ave, T14S, R14E, Section 6, Ward 3
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T09CM01440 (First Review)


RESUBMITTAL REQUIRED: Site Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the site plan with the next submittal.

This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for code full compliance for the area of expansion only.

Site Plan:


1. Please revise location map to be at a scale of 3" = 1 mile per D.S. 2-02.2.1.4.
2. Verify that all necessary existing and future sight visibility triangles are shown within site plan per D.S. 2-02.2.1.10. See site plan for notes and correct dimensions on site plan. The plotted sight visibility triangles on site plan appear to be reversed.
3. DS Sec.2-02.2.1.A.16: Indicate proposed finished floor elevation(s) and finished grades.
4. DS Sec.2.02.2.1.A.16: Provide roof drainage arrows and locations of all concentration points. Specifically show roof drainage direction and down spout locations for proposed building at pedestrian circulation areas. A detail for the dimension of the proposed scuppers that are used for collecting onsite roof drainage at all pedestrian sidewalk is required; refer to City of Tucson details. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk.
5. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. It appears that cut and fill will not be occurring for the proposed building. However, as part of the site submittal requirement estimated cut and fill quantities are required to be indicated on the plans so that it is clear to the inspector that no cut in fill is to be taking place. If not cut and fill is taking place indicate the quantity of zero (0) on the plan. Estimated cut and Fill: Cut = 0 and Fill = 0 will suffice.
6. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. Include existing and future right of ways If the distance is for both existing and future please indicate on site plan.
7. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Lester Street and 1st Ave.
8. Verify that all easement of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20.
9. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
10. D.S. 2-02.2.1.A.12 Per D.S. 2-08.3.1 a pedestrian circulation/accessible route, sidewalk is required from the proposed structure to the existing structure. A sidewalk is required between the two (2) buildings. It is not clear what is proposed on this site plan.
11. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. Provide contour interval on plan.
12. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. Provide permit number for approved existing fence.
13. Provide the site plan activity number in the lower right hand corner of each sheet per D.S. 2-02.2.1.29.
14. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
15. Provide the owner contact information.
16. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
17. All symbols on plans need to be indicated in legend. Indicate all symbols in legend.
18. Additional comments may be forthcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
07/14/2009 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
07/23/2009 PETER MCLAUGHLIN LANDSCAPE REVIEW Denied 1. The site plan must be accompanied by a landscape plan with information specified in Development Standard 2-07.0. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. The review will continue when documents are included with re-submittal.

2. A street landscape border is required along Lester Street and along 1st Avenue. A street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. No structures may be placed within the required landscape borders. Revise plan to meet code.

3. Landscape plan shall include irrigation specification design and layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

4. Detail required screening on the landscape plan. Label the screen location, height, and materials on the plan drawing. DS 2-07.2.2.A.3

5. Provide a copy of the original approved site plan and landscape plan from records.

6. Additional comments may be necessary upon submittal of a landscape and irrigation plan.
07/23/2009 PETER MCLAUGHLIN NPPO REVIEW Denied Submit NPPO plan or application for exception. If submitting an application for exception, include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property per DS 2-15.2.0.C.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/31/2009 CPIERCE1 OUT TO CUSTOMER Completed