Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T09CM01224
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/18/2009 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 12/02/2009 | DAVID RIVERA | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: 3033 N. Stone Avenue - Auto Sales T09CM01224 Site Plan (2nd Review) TRANSMITTAL DATE: December 2, 2009 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This comment was not addressed as requested. While the dimensions for a standard parking space have been added the disabled parking space and access aisle has not been dimensioned. In lieu of the parking space details requested add the word typical for the standard parking spaces dimensions and dimension the disabled parking spaces and access aisle. (Previous comment 2, Per Development Standard 2-02.2.1.A.8 Provide a typical parking space detail for a standard space. D.S. 2-02.2.1.A.8 Provide a typical parking space detail for a standard vehicle parking spaces.) 2. This comment was not addressed as requested. Provide the information as requested per the previous comment. (Previous comment 3, Per Development Standard 2-09.5.4 Lighting will be provided in a bicycle parking area such that all facilities are thoroughly illuminated. Demonstrate on the bicycle parking detail how D.S. 2-09.5.4 is met. D.S. 2-02.2.1.A.9 On the bicycle parking detail indicate how lighting will be provided to the bicycle parking.) 3. This comment was not addressed as requested. (Previous Comment 8, Based on lot dimensions of 120' x 222.5' the gross lot area is 26,700. As stated before as dedication of right-of-way is not proposed for this project the gross lot area is based on existing lot. Revised the gross lot area to reflect the correct gross lot area of 26,700 and also revise the Floor area ratio and parking calculation to reflect the correct gross lot area. D.S. 2-02.2.2.A.1 List the gross lot area on the plan. Unless you are dedicating ROW of way to the City at this time the gross lot area is for the entire lot. Until comment 4 has been addressed the gross lot area cannot be verified.) 4. This comment was not addressed as requested. (Previous Comment 9, Based on a gross lot are of 26,700 the allowed FAR is 24,030, revise the FAR calculation. D.S. 2-02.2.2.A.3 Until comments 4 and 21 are addressed the floor area ratio (FAR) cannot be verified.) 5. This comment was not addressed as requested. (Previous Comment 10, Revise the vehicle parking space calculation to reflect the correct gross lot area. D.S. 2-02.2.2.A.4 Until comments 4 and 21 are addressed the vehicle parking calculation can not be verified.) 6. After reviewing the plan and discussing with Paul Machado (Engineering Section Reviewer) the location and accessibility into and out of the loading it has been determined that the location of the loading zone must be relocated and must be designed so that the access into and out of the loading zone is functional. (See redline copy for possible location that would be acceptable) 6. Depending on how the above comments are addressed addition comments may be forth coming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t09cm01224d RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |