Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - GRADING ALL
Permit Number - T09BU01243
Review Name: RESUBMITTAL - GRADING ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/05/2009 | ANDREW CONNOR | NPPO | REVIEW | Approv-Cond | |
| 10/13/2009 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 10/14/2009 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: October 14, 2009 SUBJECT: Grading TO: Jeff Stanley LOCATION: 3038 E Fort Lowell Rd, T13S, R13E, Section 34, Ward 1 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T09BU01243 (Second Review) RESUBMITTAL REQUIRED: Grading Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal. Please include a response letter to the comments along with the corrected copies of the grading plan. Please provide a drainage report with the next submittal. Grading Plan Comments: 1. Complied 2. Complied 3. Complied 4. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 5. Delineate 100-year water surface elevations and cross sections. Note: Since FEMA information is in datum (NGVD 1929) please provide elevations in NGVD 1929 datum. 6. Complied 7. Provide the Federal Emergency Management Agency, Flood Insurance Rate Map information and Zone designation on the site plan. Acknowledge that entire property is located within special flood hazard area, Zone: AE. Note: Revise note to call out FEMA Datum as NGVD 1929 8. Complied 9. Provide documentation from COT Transportation stating that there will be no intersection widening. D.S. 2-02.2.1.A.19. It does not appear that the future right-of-way (ROW) is shown correctly. Per the MS&R map the intersection widening width is 130'. Note: Plan indicates 120' ROW, please clarify. 10. The existing ingress/egress parking & pedestrian easement will need to be modified to include the entire PAAL located south of the Wintrode Office. This comment must be addressed prior to approval of this site plan. D.S. 2-02.2.1.A.20 The sidewalk shown along the west side of the Wintrode Office building is part of the required continuous pedestrian circulation /accessible route a pedestrian access easement is required to allow access to and from the proposed office building. Note: Provide recordation information on grading plan. 11. Complied 12. Complied 13. Verify that all easements of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 14. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 15. D.S. 2-02.2.1.A.20 The sidewalk shown along the west side of the Wintrode Office building is part of the required continuous pedestrian circulation /accessible route a pedestrian access easement is required to allow access to and from the proposed office building. Note: Provide recordation information for ingress/egress pedestrian easement. 16. Complied 17. Complied 18. Complied 19. Additional comments may be forthcoming. Drainage Report: 1. Complied 2. Complied 3. Complied 4. Additional comments may be forthcoming. If you have any questions, I can be reached at Bianca.ramirez@tucsonaz.gov or 837-4928. Bianca Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |