Review Status: Completed
Review Details: LUCAPPS - OVERLAY ZONE REV
Permit Number - T08SA00290
Review Name: LUCAPPS - OVERLAY ZONE REV
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/19/2008 | PETER MCLAUGHLIN | ZONING | REVIEW | Approv-Cond | 1. Add the overlay zone case number (T08SA00290) to each sheet of the plan set in lower right corner next to the title block. Also add to general note 11 on page 1 of the site plan the case number, date of approval, and any applicable conditions of approval. |
| 08/19/2008 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Denied | 1. The grading plan, site plan and floodplain info plan (Exhibit 4 in the ERR document) indicate different grading limits and show a different orientation of the proposed soccer field from that shown on the landscape, native plant preservation, and ERR plans. As shown on the grading, site, and floodplain plans the soccer field and grading limits will extend into the area of protective fencing and will cause some of the native mesquite and desert willow trees, which are labeled as "preserved in place", to have to be removed. Revise site plans and grading plan to be consistent with the landscape plan, NPP plan and ERR plan as far as the location of the soccer field and grading limits. 2. The proposed maintenance building is also shown to be of various sizes and in different locations on the plans. Revise grading plan and site plans to be consistent with the landscape plan, NPP plan, and ERR plan concerning the location and layout of all proposed buildings and other site elements. 3. Revise the ERR plan to show the correct limits of grading clearly and to indicate the location of protective fencing. |
| 09/05/2008 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | DATE: September 5, 2008 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Desert Christian School Protected Riparian Area Review (First Review) T08SA00290 T14S, R15E, Section 03 RESUBMITTAL REQUIRED: None Floodplain delineation as shown in the submittal is accepted as shown in the report exhibits and the site plan with the note that the x-shaded areas represent 500-year floodplain areas. The 100-year (Zone AE) floodplain areas are the regulated areas for Riparian Protection. If you have any questions, I can be reached at 520.837.4927 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 09/09/2008 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES September 9, 2008 Kent A. Delph, P.E. Grenier Engineering, Inc. 5517 East 5th Street Tucson, Arizona 85711 Subject: T08SA00290 Environmental Resource Overlay Zone for 9415 East Wrightstown Road (T08CM01161) Dear Kent: Your submittal of August 6, 2008 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Environmental Resource Overlay zone submittal package as detailed in the on line comments (Landscape, DSD). THE PUBLIC COMMENT PERIOD WILL BE OPENED WITHIN THE NEXT TWO WEEKS. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 326-7508 |