Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08OT02525
Parcel: 117041900

Address:
127 W 5TH ST

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T08OT02525
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2008 JASON GREEN ENGINEERING REVIEW Approved November 14, 2008
FLOODPLAIN USE PERMIT # T08OT02525
PROJECT ADDRESS: 127 W 5th Street, Tucson AZ 85705
APPLICANT'S NAME: Nancy Bender/ Carl White
PROPERTY OWNER: Whistle Stop LLC Attn: Nancy Bender


This parcel is located within in a FEMA Special Flood Hazard Area (SFHA), Zone AE and partially within a Shaded Zone X 500-year floodplain as shown on the Flood Insurance Rate Map (FIRM), Community-Panel No. 040076 C 2226K, effective date February 8, 1999 with LOMR dated 02NOV02. The applicant is authorized to use a portion of the flood hazard area in the City of Tucson, Arizona, on the property described as:

127 W 5th St Tucson, AZ 85705; TUCSON THAT PT W2 BLK LYG N SP RR BLK 56, in a portion of Township 14 South, Range 13 East, Section 12. For the purpose of constructing a clock tower entrance to the existing building and canopies over the existing loading dock.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 11 conditions apply to this permit:

1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes or deviates from the approved plans, or, if there is any further disturbance within the floodplain and W.A.S.H. overlay other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the fire damage repair to the warehouse within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Details and General Site Plan sheets, prepared by Harris Engineering Services, dated September 16, 2008 which are made part of this permit.
4) The construction to the existing warehouse is limited to the construction shown on the approved site plan for the proposed clock tower entrance structure and loading dock canopies .
5) Electrical equipment is not allowed or permitted under this Floodplain Use Permit. Future improvements will require a separate Floodplain Use Permit and all new electrical junctions, boxes, A/C units, Evaporative Coolers, hot water heaters, etc will be required to be certified by a registered land surveyor verifying that the new electrical equipment is elevated at or above the calculated water surface elevation as shown on the Elevation Certificate submitted to show that the existing finished floor elevation of the existing warehouse is in conformance with the rules and regulations of Chapter 26 of the Tucson Municipal Code and Chapter 44 of the Code of Federal Regulations.
6) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T08OT02525 FOR INFORMATION PLEASE CALL 791-5550."
7) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
8) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
9) There shall be no stockpiling material, or storage of vehicles, other than that which is accepted by COT and as shown on the approved plans. There shall be no stockpiling or disturbance outside of disturbance limits. Construction material and vehicles shall be promptly removed once installation and construction is complete.
10) Contractor will need to call for floodplain use permit inspections by Development Services Department Engineering Division Inspection Team (791-5550) prior to and after the fixed fire damage repair.
11) See the associated activity T08CM03457.

This Floodplain Use Permit will be automatically revoked and becomes invalid for non-compliance to conditions set forth in this permit. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division.

(EXPIRATION DATE) Month: 11 Day: 15 Year: 2008


APPLICANT/CONTRACTOR: Nancy Bender/ Carl White
ADDRESS: 6473 N Foothills Dr, Tucson, Arizona 85718
PHONE: (520) 271-7605 or 271-4226
OWNER: Nancy Bender/ Carl White
ADDRESS: 6473 N Foothills Dr, Tucson, Arizona 85718
PHONE: (520) 271-7605 or 271-4226


SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/05/2011 SUE REEVES APPROVAL SHELF Completed
08/05/2011 CPIERCE1 OUT TO CUSTOMER Completed