Permit Review Detail
Review Status: Completed
Review Details: OTHER
Permit Number - T08CM03423
Review Name: OTHER
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/18/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 11-19-08 Activity: T08CM03423 Address: 441 S. Elias Av Applicant: Tania Rhodes Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. White Out is not acceptable on construction drawings. SITE PLAN: 3. Specify the location of the proposed connection to the existing sewer line. FLOOR PLANS: 4. Specify the height of all windows. 5. Indicate the location and method of drainage for the walled patio area. FOUNDATION PLANS: 6. Provide a note for termite treatment, R320 as amended. SECTIONS - DETAILS: 7. Specify 3x ledger material for roof connections to masonry walls, Figure R606.11(1). PLUMBING PLAN: 8. Show the size and location of all cleanouts, UPC 707.4, Table 7-6. Two-way cleanout is required within 2' from the building at the lower end. ELECTRICAL PLAN: 9. For single-family dwellings, the service shall not be rated less than 100 amperes, E3502.1 10. Bedroom outlets shall be protected with combination-type arc-fault breakers (receptacles, lights, and smoke detectors), E3802.12. 11. Exterior outlets at grade level shall be provided at both the front and back of the dwelling, E3801.7. These outlets shall be GFCI protected E3802.3. 12. Kitchens require two or more 2O-amp small appliance circuits to serve counter space. Such circuits shall be GFCI protected and shall not serve other rooms (except breakfast areas, pantries, etc.), E3801.3. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
11/24/2008 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
11/24/2008 | SUE REEVES | REJECT SHELF | Completed |