Permit Number: T08CM03225
Parcel: 11501148E

Address:
2381 N 4TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T08CM03225
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/02/2008 DAVE MANN FIRE REVIEW Denied The IRC and IBC require automatic fire sprinklers in R-2 units.
10/02/2008 RBROWN1 ADA REVIEW Passed NOT A COT PROJECT
10/02/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 2 OCTOBER 2008
T08CM03225/4TH AND SAHUARO RESIDENCES
REVIEWED BY RON BROWN

ACCESSIBLE REVIEW
2006 IBC/ICC 117.1
DENIED

1. Identify the accessible routes and provide spot grades along the accessible route to show compliance with section 403.3.
2. Provide one accessible parking space complete with signage, aisle and a marked crossing to the accessible route with all required ramps and detectable warning as per sections 406, 406.12 and .13.
3. Verify drive entrance compliance with COT DOT development standards.

END OF REVIEW
10/03/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 4th & Sahuaro Residence
T08CM03225
Site Plan (1st Review)

TRANSMITTAL DATE: October 3, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for a commercial site.

2. Prior to approval of this site plan by Zoning the lot split/subdivision issues must be resolved for this parcel and the parcels adjacent to the north.

3. It does not appear that all text on the plan meets the minimum 12 (0.12) minimum text size.

4. Provide building elevations so that all setbacks can be verified.

5. D.S.2-02.2.1.A.7 The following comments are in regards to the street setback for E. Sahuaro Street:
Based on LUC Section 3.2.6.5.B developing area setbacks, a setback of twenty-one (21) feet or the height of the proposed exterior building wall (H), in all circumstances, the greater setback resulting from the alternate measurement is required, this setback is measured from the nearest edge of travel lane.
Remove the "17'-5" FRONT SETBACK" from the plan as this is shown incorrectly.
Remove the "21'-0" ALLOWABLE SETBACK" and setback dashed line.
Provide a dimension from the nearest edge of travel lane, along Sahuaro St., to the southeast corner of the proposed "GABLED ENTRY CANOPY" on "UNIT #1".
Provide a dimension from the nearest edge of travel lane, along Sahuaro St., to the southeast corner of the eastern most "DORMER".

6. D.S.2-02.2.1.A.7 The following comments are in regards to the street setback for 4th Avenue:
Based on LUC Section 3.2.6.5.B developing area setbacks, a setback of twenty-one (21) feet or the height of the proposed exterior building wall (H), in all circumstances, the greater setback resulting from the alternate measurement is required, this setback is measured from the back of curb.
Provide a dimension from the ridge point perpendicular to the back of curb along 4th Ave. from all proposed units.
Provide a dimension from the proposed covered porch, on "UNIT #3" perpendicular to the back of curb along 4th Ave.

7. D.S.2-02.2.1.A.7 Based on the "TOP OF DORMER ROOF HEIGHT@21'-4", provided under keynote 4, it does not appear that "UNIT #3" will meet the required setback to the north property line.

8. D.S.2-02.2.1.A.8 Per D.S. 3-05.2.3.C.1 A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from overhanging adjacent sidewalk areas. This said provide some type of barrier to prevent vehicles from overhanging the sidewalk along the north side of "UNIT #2".

9. D.S.2-02.2.1.A.8 Provide a typical parking space detail for a standard parking space. Per D.S. 3-05. 2.3.C.2 & D.S. 3-05.0 Figure 5 show wheel spot curbing along with a dimension for its location.

10. D.S.2-02.2.1.A.8 Per D.S. 3-05.2.3.C.1 A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from overhanging adjacent unpaved areas. This said there does not appear to be any barrier or curbing along the south side of the entrance parking area access lane (PAAL) and adjacent parking space.

11. D.S.2-02.2.1.A.12 Per D.S. 3-05.2.2.D provide a minimum distance of three (3) feet between the back of spur, located at the west end of the parking and the property line.

12. D.S.2-02.2.1.A.12 Per D.S. 2-08.3.1 within all development, a continuous pedestrian circulation path/accessible route is required. This path must connect all public access areas of the development and the pedestrian circulation path located in any adjacent streets. The areas within the development which must be connected include, but are not limited to, all buildings. This said provide on site a continuous pedestrian circulation path/accessible route that connects all buildings.

13. D.S.2-02.2.1.A.13 If applicable show the location, type, size and height of existing and proposed free standing signage or billboards on the site.

14. D.S.2-02.2.1.A.19 Provide a dimension for the travel lane along E. Sahuaro Street.

15. D.S.2-02.2.1.A.20 If applicable show all easements of record, along with the recordation information, docket and page, on the plan.

16. D.S.2-02.2.1.A.28 Provide the existing zoning of the adjacent parcels across the streets on the plan.

17. D.S. 2-02.2.1.A.31 Show the existing and proposed use on the plan. The proposed use should be shown as "FAMILY DWELLING, MULTI FAMILY, "K", SUBJECT TO: SECTION 3.5.7.1.F".

18. D.S. 2-02.2.1.A.32 Zoning acknowledges the locations shown for the proposed "TRASH/RECYCLING RECEPTIACLES". A Development Standards Modification Request (DSMR) maybe required, see Engineering comments.

19. Per D.S. 2-02.2.2.A.3 Provide a density calculation on the plan.

20. Additional comments may be forth coming depending on how each comment has been addressed.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t08cm03225.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents.
10/06/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. A 10' interior landscape border is required along site boundaries of the adjacent residential properties per LUC Table 3.7.2-I

2. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border(s) per LUC 3.7.2.4. Additional trees are required for street and interior landscape borders

3. A 5' continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I

4. A 5' wall is required to screen vehicle use area from adjacent residential properties per LUC Table 3.7.2-I. All walls must be of masonry material or masonry with a stucco or textured finish.

5. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.

6. All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution including the area between the right-of-way line and sidewalk and the area between the sidewalk and the curb.

7. Submit NPP plan or Application for Exception: Include with application documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property per DS 2-15.2.0.C


8. Landscape plan shall include irrigation layout per DS 2-06.5.4.A & DS 2-06.5.4.B including source of irrigation, sleeves for driveways and sidewalks, locations of valves, low-flow bubblers or drip irrigation.

9. All landscape areas will be depressed to accept water flow from roofs, PAAL, and parking areas. Show by detail or spot elevations how landscape areas will accommodate water harvesting.

10. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

11. Additional comments may apply.
10/07/2008 ANDREW CONNOR NPPO REVIEW Denied Submit NPP plan or Application for Exception: Include with application documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property per DS 2-15.2.0.C
10/14/2008 PAUL MACHADO ENGINEERING REVIEW Denied To: W.G. Gasser DATE: October 14, 2008
3102 E. Seneca Street
Tucson, Arizona 85716

SUBJECT: 4th and Sahuaro Res., 2381 N. 4th Ave.
Site plan T08CM03225 (First Review)
T14S, R13E, Section 01

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement.

The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. Depict all wheelchair ramps per the current development standards.
3. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The svt's are not drawn properly. See the redlines for direction.
4. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11.
5. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
6. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14.
7. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
8. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. It appears that more 50 cy of cut/fill will be needed to "balance" the site out. Revise the cut/fill quantities for a more realistic number or submit cut sheets w/ earth work qualities.
9. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19.
10. Sidewalks, curbs and wheelchair ramps are required where applicable per D.S. 3-01.3.0 and installed with "Detectable Warnings" per ADAAG.
11. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
12. Location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22.
13. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
14. Show Site plan number (T08CM03225) on all sheets per D.S. 2-02.2.1.29.
15. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Obtain permission from environmental services for the use of "roll-out" containers.
16. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
17. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
18. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
19. List the consulting engineer and the owner/developer on the plans with the pertinent information.
20. Add note: "Depress all landscaped areas 6" maximum for water harvesting". Provide depressed areas for water harvesting.
21. "A grading permit will be required for this project. Submit 2 sets of grading plans, upon completion and submittal of a grading permit application. A grading permit may not be issued prior to the site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans".

Drainage Statement:
1. Please include a response letter to the comments along with the corrected copies of the DS.
2. A Drainage Statement is a brief description of drainage conditions applicable for a site which are not affected by 100 year flows of 100 cfs, of more……per S.M.D.D.F.M., chap. II, 2.1.2. The DS must be submitted along with the site plan and accepted with the approval of the grading plan.
3. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.2.
4. Show the project address or administration address on the cover sheet of the DS.
5. If applicable, add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DS.

If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4932 office
(520) 879-8010 fax
C:/2381 N. 4th Ave site.doc
10/30/2008 CPIERCE1 PLUMBING-COMMERCIAL REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/30/2008 CPIERCE1 OUT TO CUSTOMER Completed