Review Details: SITE
Permit Number - T08CM02820
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/20/2008 | DAVE MANN | FIRE | REVIEW | Denied | Please include the following design criteria to the plans. 1. Flow data (static pressure, residual pressure, GPM) Available from the Fire Department (520) 791-3234 2. The standard to be used in development of sprinkler system. (NFPA 13, NFPA 13R, or NFPA 13D) 3. The hazard classification of the building, including any special hazards. 4. The density required of the water supply. Please indicate existing fire hydrant location(s), with dimensions to buildings and/or property lines. Refer to City of Tucson amendments to the 2006 International Fire Code (section 508) for spacing and location requirements. Turn around for Waste Management (dumpster) is also required for Fire Department. Minimum width neccessary is 20'. Please revise. |
| 08/20/2008 | RBROWN1 | ADA | REVIEW | Passed | NOT A COT PROJECT |
| 08/20/2008 | RONALD BROWN | ZONING HC SITE | REVIEW | Denied | 1. The accessible parking is located in the most remote place possible for access to apartments. Please relocate to a more central location. |
| 08/21/2008 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Reza Apartments T08CM02820 Site Plan (1st Review) TRANSMITTAL DATE: August 21, 2008 COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance. 2. D.S.2-02.2.1.A.6 If applicable for all proposed buildings and structures, including location, size, height, overhangs, canopies, and use. There appears to be some type of porch(s) on the front of the proposed building. 3. D.S.2-02.2.1.A.7 The "STREET SETBACK = 21' FROM OUTSIDE EDGE OF NEAREST TRAVEL LANE" is not correct. As Blacklidge is not on the MS&R map LUC Section 3.2.6.5.A applies, 20' or 1-1/2 the height measured from property line. 4. D.S.2-02.2.1.A.7 Based on the provided building height of 23' BLDG B does not appear to meet the required setback to the east property line. Per LUC Section 3.2.6.4 development designator "K" the required setback would be 17.25', proposed setback is 16.-4". 5. D.S.2-02.2.1.A.7 The proposed office building does not meet setbacks to the street property line. Per LUC Section 3.2.6.5.A the required setback is 20'-0", proposed is 10'-0". 6. D.S.2-02.2.1.A.9 Show the location of the required bicycle parking. Provide an off-street bicycle parking detail that includes, materials for lighting, paving, fully dimensioned layout; specific type of rack and the number of bicycles it supports. The fully dimensioned layout needs to meet the requirements of D.S. 2-09.5.1 & 5.2. 7. D.S.2-02.2.1.A.12 Per D.S. 3-05.2.2.B.1 A minimum setback distance of five (5) feet for a pedestrian refuge area must be maintained between any enclosed structure and a PAAL. Also per D.S. 2-08.4.1.B A sidewalk will be provided adjacent and parallel to any PAAL on the side where buildings are located. This said along the west side of the proposed office building a five (5) foot pedestrian refuge area and minimum four (4) foot wide sidewalk is required. 8. D.S.2-02.2.1.A.13 If applicable show the location, type, size, and height of existing and proposed signs on the plan. 9. D.S.2-02.2.1.A.19 Provide a dimension for the right-of-way for Blacklidge Drive. 10. D.S.2-02.2.1.A.20 If applicable show all easements of record graphically on the plan along with the recording docket and page reference. 11. D.S.2-02.2.1.A.25 If applicable show the proposed site lighting layout on the plan. 12. D.S. 2-02.2.1.A.31 Revise the "SUBJECT TO: LUC SECTION 3.5.7.1" to read "SUBJECT TO: LUC SECTION 3.5.7.1.F". 13. D.S.2-02.2.2.A.4 The bicycle parking calculation shown is not correct. Per LUC 3.3.4 RESIDENTIAL USE GROUP, Bicycle: Eight (8) percent for multifamily projects of four (4) or more units - fifty (50) percent Class 1 and fifty (50) percent Class 2. 20 x 4% = 1.6 or 2 required. Per LUC Section 3.3.7.8.A Bicycle Parking Requirements. Any use providing less than fifty (50) motor vehicle parking spaces may substitute Class 2 spaces for Class 1 spaces. 14. Keynote 18 calls out a "FUTURE SECURITY GATE". The gate needs to be review and approved by COT Traffic Engineering, Jose Ortiz 520-791-4259, prior to approval of the site plan. 15. Additional comments may be forth coming depending on how each comment has been addressed. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956. C:\planning\site\t08cm02820 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents. |
| 08/26/2008 | ANDREW CONNOR | NPPO | REVIEW | Denied | Provide acceptable documentation, which clearly indicates that the project will not substantially impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. Landscape plan must show the ultimate location(s) and/or disposition of mitigation or transplanted native plant material DS 2-115.3.5.B.2. |
| 08/26/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1.A 5' wall is required to screen residential properties from vehicle use area per LUC Table 3.7.2-I. 2. If a new development is using an existing screen on an adjacent property to meet screening requirements, a copy of the recorded covenant locating the existing screen(s) on adjacent property is required. 3. A minimum of 34 sq. ft and 4' in width must be provided for each canopy tree DS 2-06.3.3.C. Dimension all planters. 4. The planting plan and layout calculations will include both the proper and common name of existing vegetation to remain in place. 5. Provide acceptable documentation, which clearly indicates that the project will not substantially impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. 6. Landscape plan must show the ultimate location(s) and/or disposition of mitigation or transplanted native plant material DS 2-115.3.5.B.2. 7. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan. 8. Additional comments may apply. |
| 09/11/2008 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Denied | DATE: September 15, 2008 SUBJECT: Site Plan TO: ASI LOCATION: 1447 E Blacklidge, T13S, R14E, Section 31, Ward 3 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T08CM02820 (First Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal. Site Plan: 1. Please include a response letter to the comments along with the corrected copies of the site plan. 2. The most recent aerial photo of the building does not match what is depicted on the site plan. Please modify site plan to represent actual footprint of buildings and/or clarify. Identify and label existing and proposed building(s) on site plan. 3. Within the location map provide Section, Township, and Range; section corners and scale should be drawn at a minimum of 3" = 1 mile. 4. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. 5. Label near side sight visibility triangles per D.S. 2-02.2.1.10. 6. DS Sec.2-02.2.1.A.10: Provide existing and future site visibility triangles (SVT), labeled and dimensioned, if there is only one SVT label as existing/future. 7. DS Sec.2-02.2.1.A.11 & DS Sec.3-01.3.2.C: Depict and label radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance along Blacklidge. The curbs should be constructed at the edge of pavement and entirely on the subject property, which must also be depicted on the site plan. 8. Verify that all vehicular, bicycle, pedestrian, and handicapped circulation have been clearly identified on the site plan per D.S. 2-02.2.1.12. 9. Please provide drainage patterns and finished grades including top of curbs per D.S. 2-02.2.1.16. 10. DS Sec.2-02.2.1.A.16: Indicate drainage patterns and put drainage symbols in legend, proposed finished floor elevation(s), and finished grades. 11. DS Sec.2.02.2.1.A.16: Provide drainage arrows and locations of all concentration points. Specifically show roof drainage and down spout locations for proposed buildings at pedestrian circulation areas. A detail for the dimension of the proposed scuppers that are used for collecting onsite roof drainage at all pedestrian sidewalk is required, refer to City of Tucson details. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk. 12. Label dimensioned right-of-way, label both existing and future ½ right of way D.S. 2-02.2.1.19. 13. DS Sec. 2-05.2.4.H.2: Provide the right-of-way (ROW) recordation information for Blacklidge Dr. 14. DS Sec.2-02.2.1.A.19: If applicable label the future sidewalk and curb area on the site plan to verify that all improvements are located outside of the future ROW. 15. Verify that all easement of record have been graphically shown on the plan together with recording docket and page per D.S. 2-02.2.1.20. 16. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 17. Indicate contour interval on site plan. 18. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27. 19. Show site plan activity number on each sheet in the lower right hand corher of all sheets per D.S. 2-02.2.1.29. 20. See attached detail and verify that trash enclosure meets the minimum standards City of Tucson Development Standard No 6-01.0 Solid Waste Disposal (Refuse) - dimension 10 feet by 10 feet minimum inside clear dimension per D.S. 2-02.2.1.32 and D.S. 6-01.0. 21. DS Sec.2-02.2.1.A.32: Label and show 14' X 40' clear approach. 22. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 23. Please show a typical cross section of the P.A.A.L. and call out the percentage of slopes. Call out the grade break at the driveway. 24. Add note: "Depress all landscaped areas 6" maximum for water harvesting". 25. All symbols on plans need to be indicated in legend. Indicate all symbols in legend. 26. A grading permit will be required for this project. Submit 3 sets of grading plan with text, upon completion and submittal of a grading permit application. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans. 27. Verify that all text is a minimum 0.12 font. 28. Change FINE on handicap sign to read $532 29. Revise text so that it is not overlapping. 30. Provide dimension for back up spur and lable radaii of all curbs onsite. 31. Water harvesting areas are not acceptable adjacent to building(s) without geotechnical recommendations for setbacks for retention structures. 32. Road elevation appears to be higher than onsite elevations. Is all drainage from road being directed through site? 33. Additional comments may be forthcoming. DRAINAGE REPORT 1. Revise onsite watershed basin and incluse drainage from streets approaching site. 2. Provide retention/detention calculations with equations to show onsite imperviousness and perviousness. Indicate the change with accurate basin calcualtions. 3. Appears to be no evidence that 70 cfs is existing at the northwest corner of project. 4. Drainage Report is showing a low point to the west of project. 5. Topo indicates low points and it appears that proposed design would cause and adverse impact to the property located to the northwest corner. 6. Offsite drainage area doesn't appear to be correct. Drainage design should be revised along with drainage map. 7. Additional comments may be forthcoming. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/24/2008 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |