Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T08CM01986
Parcel: 12009317A

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T08CM01986
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/06/2008 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET G1.0; CODE ANALYSIS DATA: BUILDING CODE IS THE IBC.
2. SHEET A1.0; FLOOR PLAN: PER IBC TABLE 2902.1, BUSINESS PORTION OF THE BUILDING REQUIRES ONE MEN'S AND ONE WOMEN'S RESTROOM (ONE PER 25). FACTORY PORTION OF THE BUILDING REQUIRES ONE MEN'S AND ONE WOMEN'S RESTROOM (ONE PER 100). SECTION 2902.2 REQUIRES ONE RESTROOM FOR EACH SEX. AN ADDITIONAL FACTORY RESTROOM IS REQUIRED. VERIFY.
3. SHEET A4.0; REFLECTED CEILING PLAN: THESE ARE FINAL, STAMPED DRAWINGS. REMOVE 'PRELIMINARY'.
4. SHEET S0.1: DEFERRED SUBMITTALS MUST BE APPROVED BY THE BUILDING OFFICIAL DURING THE PLAN REVIEW PROCESS.
5. SHEET S0.1: SPECIAL INSPECTION FORMS MUST BE SUBMITTED DURING THE PLAN REVIEW PROCESS.
6. SHEET S1.0; CALCULATIONS: BUILDING FOOTINGS AND FOUNDATIONS ON SUBMITTAL SETS MAY NOT BE A DEFERRED SUBMITTAL. FINAL CALCULATIONS MUST BE SUBMITTED BY THE ENGINEER OF RECORD BEFORE THE DRAWINGS CAN BE APPROVED.
7. SHEET A2.0/SECTIONS 1 & 2; SHEET S2.0/SECTIONS 107,108 & 109: COORDINATE ARCHITECTURAL AND STRUCTURAL SECTIONS CONCERNING THE METAL BUILDING FRAME LOCATION IN RELATION TO THE MASONRY WALL.
08/06/2008 DAVE MANN FIRE REVIEW Approved
08/07/2008 JOHN WILLIAMS COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Completed Impact Fee's Do Apply; West District; 10,000 Square Feet Factory/Office; $20,960
08/08/2008 ERIC NEWCOMB ZONING HC SITE REVIEW Denied 1. SEE BUILDING COMMENTS.
08/15/2008 GERRY KOZIOL WWM REVIEW Denied
08/28/2008 TERRY STEVENS ZONING REVIEW Denied 08/28/2008

Development Services Department
Zoning Review Section

Terry Stevens
Lead Planner

Comments:

1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the building plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next building plan submittal.

3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved site plan. Additional comments may be forthcoming.
08/29/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Revise the site drawing to show the location of the reduced pressure backflow preventer assembly. Reference: Section 103.2.3, UPC 2006.
2. Revise the site drawing to show the route of the medium pressure natural gas piping with its easement. Reference: Section 103.2.3, UPC 2006.
3. Show how the water heater is being connected to the building structure and provide calculations to show that the building structure is not being adversely affected. Reference: Sections 310.0 and 314.5, UPC 2006.
4. Clarify the total load and developed length of piping for the gas meter. The note on detail B/P1.0 calls out a total load of 1,482 CFH at 76 feet but the diagram shows connected load of 150 CFH at 43 feet. Further, the gas meter load schedule on sheet P1.0 calls out a load of 365 CFH and detail 2/P1.0 shows a developed length of less than 15 feet.
5. Clarify the pipe sizes used for the water distribution system. Why is the pipe size increased from 1-1/4" to 1-1/2" after the pipe enters the building? Reference: Section 103.2.3, UPC 2006.
6. Clarify the hot water distribution system; detail 204/P2.0 shows a recirculating hot water system but neither the plumbing plan nor the water isometric show a recirculating system. Reference: Section 103.2.3, UPC 2006.
7. Provide calculations to show that combining the T&P relief with the pan drain of the water heater complies with Sections 508.4 and 608.5, UPC 2006.
8. Provide specifications for the proposed sand/oil interceptor. Show that the interceptor complies with the requirements of both 1016.0 and 1017.0, UPC 2006. Reference: Section 103.2.3, UPC 2006.
9. Site plan keynote #13 calls for a reclaimed water circul. [sic] system. Provide connection details and listing information. Reference: Section 103.2.3, UPC 2006.
08/29/2008 ROBERT SHERRY WATER REVIEW Approved
08/29/2008 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied 1. Provide energy code compliance calculations using the correct climate zone for Pima County < 4,000 feet. Reference: Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation. Reference: Sections 101.4 and 104.2, International Energy Conservation Code 2006.
2. Show how the fan coils and unit heaters are being connected to the building structure and provide calculations to show that the building structure is not being adversely affected. Reference: Section 302.1, IMC 2006.
3. Revise the ventilation calculations to take into account the different occupancy loads in the project space. Reference: Sections 403.3 and 403.3.2, IMC 2006.
09/03/2008 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 520.837.4907 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Provide electrical power for WH-1. Please coordinate with the Plumbing plans.
2. Provide electrical power for the 3-phase, 75 HP Steam Cleaner. Reference Sheet P2.1, Plumbing Fixtures.
3. Account for the electrical load for the TTB on Ckt TM-24.
4. Please provide cut sheets for the equipment referred to as "BIG ASS FAN" on Sheet A4.0. We need to be clear with respect to the electrical requirements and weight.
5. Provide mounting information for "Big Ass Fan", and coordinate with Sturctural Plans Examiner and NEC 314.27 (D), 422.18, and 422.20.
6. Please correct electrical load for Phase B on Sub-Feed to Pnl TL, as allocated on Ckt 40 of TM to read, "10466", not 9266. Update all effected calculations.
7. Four Fixtures "A" at 400 VA each, at 125% would be a minimum of 2000VA on Ckts TL-1, TL-3, and TL-5, before the addition of the exit and egress lighting. Please check all lighting circuits, and re-evaluate panel capacity.
8. Please modify the #6 GND in the run between the gutter and the CT Can per NEC Table 250.66, to read, "#4."
9. The 65/10K series rating on Panels TM and TL would require a 3-tiered system, not available commercially.