Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T08CM01161
Parcel: 133040030

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08CM01161
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/13/2008 DAVE MANN FIRE REVIEW Approved
11/18/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
11/18/2008 PETER MCLAUGHLIN ZONING REVIEW Denied A continuous pedestrian circulation path is required to provide an accessible connection between the development and the public right-of-way. Revise the plan to demonstrate compliance. If no sidewalk connection is proposed to the Wrightstown Road right-of-way, approval of a Development Standard Modification Request (DSMR) is required. If a DSMR is sought and approved add the case number, date of approval, and any conditions imposed to the general notes, and add the case number to the lower right hand corner of each sheet of the site plan. DS 2-08.3.1
11/19/2008 PETER MCLAUGHLIN NPPO REVIEW Approv-Cond 1. A temporary holding nursery for transplants is shown on the native plant preservation plan sheet NP-1. Remove the note on this sheet stating that a temporary nursery is not necessary.

2. The Environmental Resource Zone (ERZ) overlay application (T08SA00290) must be approved prior to final site plan approval. Add date of approval and any conditions to the notes.
11/19/2008 PETER MCLAUGHLIN LANDSCAPE REVIEW Approved
12/01/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. A separate plumbing permit is required for the installation of a private sewer collection system. Reference: Title 18, R18-9-E302, 4.02 General Permit, Arizona Administrative Code.
2. Where the finish floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system (e.g. the elementary school, gymnasium, and maintenance buildings), a backwater valve shall be installed in the building drain or branch of the building drain serving that floor. Reference: Section 710.1, UPC 2006, as amended by the City of Tucson.
12/12/2008 LOREN MAKUS ENGINEERING REVIEW Denied Revise the ROW dedication note to reflect the covenant for future dedication. Include recordation.
I will review this plan over the counter when this revision is complete.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/15/2008 DELMA ROBEY OUT TO CUSTOMER Completed