Permit Number: T08CM00838
Parcel: 13811073B

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T08CM00838
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2008 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Approved
03/20/2008 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
03/20/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Considering the restroom clearances required by Section 604.3, ANSI A117.1-2003 and the maximum trap arm length required by Table 10-1, UPC 2006, a 1-1/2" trap arm can not be used if the wet vent is located directly behind the center of the water closet.
03/26/2008 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
03/26/2008 CPIERCE1 WWM REVIEW Needs Review