Permit Number: T08CM00634
Parcel: 13502134H

Address:
7090 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T08CM00634
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2008 DAVE MANN FIRE REVIEW Approved
06/25/2008 RONALD BROWN ZONING HC SITE REVIEW Denied 25 JUNE 2008
T08CM00634/MCDONALD'S 22ND AND KOLB
REVIEWED BY RON BROWN

ACCESSIBLE REVIEW
2006 IBC/ICC 117.1
DENIED: SEE COMMENTS BELOW

I. SHEET 1 of 3
A. PROVIDE AND IDENTIFY ACCESSIBLE ROUTE THROUGHOUT SITE TO ALL BUILDING ENTRANCES AND EXITS AND PARKING FACILITIES AND TO NEAREST PUBLIC TRANSPORTATION POINT AS PER 2066 IBC, SECTION 1104 AND ICC 117.1, SECTION 402.
1. SHOW LOCATION OF NEAREST PUBLIC TRANSPORTATION DROP OFF POINT.
B. DENOTE GOVERNING ACCESSIBILITY CODE; 2006 IBC/ICC 117.1 FOR PRIVATE PROPERTY, DENOTE RIGHT OF WAY ACCESSIBILITY STANDARDS; COT DOT STANDARDS FOR CURB RAMPS AT DRIVE WAYS AND ALL PUBLIC R.O.W. ACCESSIBILITY REQUIREMENTS.
II. SHEET 2 of 3
A. AT THE NEW ACCESSIBLE, MARKED CROSSING RAMP OF THE EXISTING BUILDING TO THE WEST, DELETE THE DETECTABLE WARNINGS SHOWN AND PROVIDE ONE 2' DEEP DETECTABLE WARNING STRIP AT THE BEGINNING OF THE MARKED CROSSING. 2006 IBC/ICC 117.1, SECTION 406.12
B. PROVIDE A DETECTABLE WARNING AT THE ISLAND CROSSING, 2006 IBC/ICC 117.1, SECTION 406.14
C.
III. SHEET 3 OF 3:
A. PROVIDE A "VAN ACCESSIBLE" SIGN ON THE SIGN POLE.

END OF REVIEW
06/25/2008 TERRY STEVENS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Terry Stevens
Lead Planner

PROJECT: T08CM00634
7090 E. 22nd Street
Site Plan

TRANSMITTAL DATE: 3/5/08

COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The crosswalks indicated between the parking spaces (along the north and west parking spaces) are required to be physically separated (raised) sidewalks. The handicap ramps and truncated domes are then required at the end of the sidewalk immediately before entering the PAAL.

2. Provide a barrier at the rear of the loading zone in order to prevent the trucks from interfering with the drive thru lane.

3. These comments are minor in nature and can be reviewed over the counter by setting an appointment with me.

If you have any questions about this transmittal, please call Terry Stevens, (520) 837-4961

C:\planning\cdrc\DSD\T08CM00634-2.doc
06/30/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the following information:
a. the location and size of the water meter
b. the location of the main water lines
c. the location of the gas meter (if any)
d. the location and size of the public sanitary sewer
e. the approximate point of connection to the public sanitary sewer
f. the location, invert, and rim elevation of the next upstream manhole
Reference: City of Tucson Development Standard No. 2-05.0 2.3 and Section 103.2.3, UPC 2006.
07/03/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: July 8, 2008
SUBJECT: Site Plan
TO: Anthony Herrera
LOCATION: 7090 E 22nd, T14S, R15E, Section 19, Ward 4
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T08CM00634 (Second Review)


RESUBMITTAL REQUIRED: Site Plan and Drainage Statement

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan and drainage statement for the above referenced property. Engineering Division does not recommend approval of the site plan at this time. Please address the following review comments prior to the next submittal.

Please include a response letter to the comments along with the corrected copies of the site plan.

Site Plan:

1. Complied.
2. See comments from Ron Brown for all handicap access issues.
3. Complied.
4. Complied.
5. Complied.
6. DS Sec.2-02.2.1.A.10: Provide existing and future site visibility triangles (SVT). Add sight visibility triangles for the intersection of 22nd Street and Kolb Road.
7. Complied.
8. See comments from Ron Brown for all handicap access issues.
9. Complied.
10. Complied
11. Complied
12. Complied
13. Complied
14. Complied
15. Complied
16. Complied
17. Complied
18. Complied
19. Complied
20. Complied
21. Complied
22. Complied
23. Complied
24. See comments from Ron Brown for all handicap access issues.
25. Complied
26. Complied
27. Complied
28. Complied
29. Revise Fine on handicap sign to read $518 FINE.
30. Additional comments may be forthcoming.

Drainage Statement:

1. Complied
2. Complied
3. Complied
4. Complied
5. Additional comments may be forthcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
07/08/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Revise the landscape plan to verify the entire site meets minimum requirements, the planting plan and layout calculations will include the location, size, and name of existing vegetation to remain in place.

2. Street landscape borders shall be located entirely on site, except that, if approved by the City Engineer or designee LUC 3.7.2.4.3. Obtain permission for use of the ROW

3. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4

4. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g.

5. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4.

6. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I. Identify screening elements.

7. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.

8. All landscape areas will be depressed to accept water flow from roofs, PAAL, and parking areas. Show by detail or spot elevations how landscape areas will accommodate water harvesting.

9. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

10. Additional comments may apply.
07/09/2008 ANDREW CONNOR NPPO REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
07/10/2008 CPIERCE1 OUT TO CUSTOMER Completed
07/10/2008 SHANAE POWELL REJECT SHELF Completed