Review Date Reviewer's Name Type of Review Description Status Comments
12/11/2008 ANDREW CONNOR NPPO REVIEW Denied Submit a copy of the approved site & landscape plans for reference. The grading application will be reviewed for compliance when the approved documents are included in the submittal.
12/11/2008 ANDREW CONNOR ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: T08BU02091
Grading Plan (1st Review)

TRANSMITTAL DATE: December 11, 2008

1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed.

2. Zoning could not verify that the grading plan was in compliance with the approved site plan. Please submit two copies of the approved and stamped site, landscape, and NPPO plans with the next grading plan submittal.

3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956

C:\planning\grading\t08bu02091

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Approved site plans and additional requested documents
12/26/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: December 29, 2008
SUBJECT: Grading Plan
TO: Wally Gasser
LOCATION: 2381 N 4th Avenue, T14S, R13E, Section 1, Ward 3
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T08BU02091 (First Review)

RESUBMITTAL REQUIRED: Grading Plan

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed grading plan for the above referenced property. Engineering Division does not recommend approval of the grading plan at this time. Please address the following review comments prior to the next submittal.

Provide a response letter to the comments along with the corrected copies of the grading plan.

Grading Plan:
1. Revise note 20 to read: "Depress all landscaped areas a maximum of 6" for water harvesting"
2. Provide grading plan number in the lower right hand corner of each sheet. In addion add "DS08-60" to the grading plan.
3. Correct section number 13 to 11, within the location map.
4. Provide legand and show all symbols in the legend, provide explination of each symbol.
5. Call out surface paving material.
6. Reference development standard detail for driveway design.
7. Show details of all surface materials.
8. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
9. Cut or fill slopes require a 2' minimum setback from property line.
10. Drainage patterns with percent slopes (Show patterns within the first 100 feet from the property line).
11. Flow arrows, grades and flow rates within and adjacent to site to show drainage scheme.
12. Additional comments may be fothcoming.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez, CFM
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
Tucson, Arizona 85726-7210
(520) 837-4928 office