Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T07CM03927
Parcel: 12906470B

Address:
2619 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T07CM03927
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/30/2008 RONALD BROWN ZONING HC SITE REVIEW Approved
07/01/2008 STEVE SHIELDS ZONING REVIEW Denied DSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 2619 E. 22nd
T07CM03927
Site Plan (2nd Review)

TRANSMITTAL DATE: July 1, 2008

COMMENTS: Please resubmit revised drawings and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. This site plan was reviewed for compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for full code compliance for the entire site due to a change of use.

2. This comment was not addressed. Per the most recent aerial photos the footprint of the existing structure shown on the plan does not match what the aerial photos show. Please clarify.

3. This comment was not addressed. Per the most recent aerial photos provide documentation, a copy of the last approved site plan that approves the addition that has been added to the north side of the existing structure.

4. As it appears that Sheet SI-02, Zoning Plan, is the site plan provide the requested dimensions on Sheet SI-02.D.S. 2-02.2.1.A.6 Provide overall dimensions for the existing structure on the plan.

5. This comment was not addressed. D.S. 2-02.2.1.A.8 The dimension for mounting height of the handicapped sign is incorrect. The 7'-0" dimension should be from the bottom of the main sign, not the van accessible sign.

6. D.S. 2-02.2.2.A.2 Once the floor plan is clarified, see comment 2 above, the gross floor area can be verified.

7. D.S. 2-02.2.2.A.4 Once the building gross floor area is clarified, see comment 21 above, the parking calculation can be verified.

8. Per Sheet SI-01 it appears that some demolition is planned to the northwest corner of the building, a demolition permit is required. Comments 2, 3, 6 & 7 will be addressed once the demolition permit has been approved.

9. Ensure that all changes to the site plan are reflected on the landscape plan.

10. Zoning is willing to provide an over-the-counter review once the above comments have been addressed. Please call or email to schedule the appointment.

If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956.

C:\planning\site\t07cm03927-2nd.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents
07/09/2008 BIANCA RAMIREZ ENGINEERING REVIEW Denied DATE: July 9, 2008
SUBJECT: Site Plan and Change of Use
TO: J.A.C.A. Design
LOCATION: 2619 E 22nd Street, T14S, R14E, Section 17, Ward 5
REVIEWERS: Bianca Ramirez, CFM
ACTIVITY: T07CM03927 (Second Review)


RESUBMITTAL REQUIRED: Site Plan and Drainage Statement

SUMMARY: Engineering Division of Development Services Department has received and reviewed the proposed site plan and drainage statement for the above referenced property. Engineering Division does not recommend approval of the site plan or drainage statement at this time. Please address the following review comments prior to the next submittal.

Site Plan:

1. It is difficult to know if the items have been addressed. Ensure that a response letter to the comments along with the corrected copies of the Site Plan is submitted with next review.
2. Provide demolition permit number for the area that has been called out as demolished.
3. See comments by Ron Brown for all handicap related comments.
4. Complied
5. Complied
6. Complied
7. Complied
8. DS Sec.2-02.2.1.A.11 & DS Sec.3-01.3.2.C: Depict curb returns for MS&R and label 25-feet radii concrete curbs per City of Tucson/Pima County Standard Detail 213 (PC/COT SD 213) at the driveway entrance along 22nd Street. The curbs should be constructed at the edge of pavement OR get approval from Transportation Department.
9. Revise the driveway location to meet the requirements per City of Tucson, Transportation Access Management Guidelines, Guideline 5.4.1 states entrance and exit drives crossing arterial and collectors are limited to two per three hundred feet of frontage along any major roadway. The nearest pavement edges spaced at least eighty feet apart. Guideline 5.4.1 states a minimum of one hundred and fifty feet, measured at curbline, shall separate the nearest pavement edge of any entrance or exit driveway and the curbline to any signalized intersection with arterial and collector roadways. Contact Jose Ortiz, Civil Engineer in regards to Transportation Management Guidelines. Provide approval letter from TDOT for driveway.
10. Complied.
11. See comments by Ron Brown for all handicap access comments.
12. DS Sec.2-02.2.1.A.12: Label existing sidewalk dimension. 6' sidewalk required along MS&R. If sidewalk is less than 6' provide photo documentation showing sidewalk condition.
13. Fully dimension loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. Provide (label and dimension) the required onsite maneuvering area(s).
14. Complied
15. Complied
16. Provide a note stating that the site plan is in conformance with the MS&R overlay zone criteria and label 22nd Street as MS&R.
17. Complied
18. Complied
19. DS Sec.2-02.2.1.A.20: Provide on the site plan all easements for existing and proposed utilities (water, gas, electric) and public/private sewer lines. The easements must be shown graphically on the plan together with recording docket and page reference. Verify that all easements have been referenced by either a detail or note.
20. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
21. Provide contour interval on plan - preferably below the north arrow and scale.
22. Complied
23. Show site plan activity number on the lower right corner of each sheet per D.S. 2-02.2.1.29.
24. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Provide detail with dimensions for refuse container on the site plan, the enclosure must have a minimum inside clear dimension of 10 feet by 10 feet between steel bollards that are required between the container and the enclosure's rear and sidewalk. Refer to DS Sec.6-01.4.2 for specifications and requirements on access, placement of containers, bin enclosure and construction. For curbside pickup a letter of approval will be required from COT Environmental Services and a Development Standard Modification Request (DSMR) may be required prior to site plan approval. Detail was not provided in submittal please provide for review.
25. DS Sec.2-02.2.1.A.32: Label and show the maneuverability for refuse vehicles in plan view at the proposed refuse container location. Positioning of trash area should allow for 14' X 40' clear approach, show access dimensioning to proposed trash enclosure.
26. Note added.
27. Complied
28. Roof down spout locations for buildings at pedestrian circulation areas have been acknowledged. Provide detail for the dimension of the proposed scuppers that are used for collecting onsite roof drainage at all pedestrian sidewalks are required, refer to City of Tucson details. Any scuppers proposed under the sidewalk will be designed and constructed to convey the 10-year flood flow. Provide a drainage statement showing scupper calculations that demonstrate that the 10-year flood flow is contained under the sidewalk. Scupper needs to be provided just south of building so that flow under new sidewalk is established.
29. Complied
30. Complied
31. Complied
32. Handicap sign to be installed 7'0" to finished grade from the bottom of the handicap sign. In addition, sign is to specify $518.00 Fine and T.C.C. 20-222. Modify accordingly included detail.
33. Complied
34. Additional comments may be forthcoming depending on conditions.

Drainage Statement:

1. Include a response letter to the comments along with the corrected copies of the Drainage Statement.
2. The proposed Drainage Statement must provide a discussion with calculations for the proposed scuppers to ensure that scuppers contain the 10-year event under the sidewalks.
3. Identify the 100-year floodplain boundary per the City of Tucson Flood Hazard study performed by J.E. Fuller and Associates. Provide the date of the study along with the title of the report. In addition, provide information from the previous study including but not limited to a floodplain boundary map and an aerial photograph that shows the location of the property and all offsite/onsite floodplains to ensure that they do not affect the proposed building. Add floodplain boundary on site plan.

If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov

Bianca C. Ramirez
Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 837-4928 office
(520) 879-8010 fax
07/09/2008 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Street landscape borders shall be located entirely on site. All planting and irrigation that is proposed within the ROW must receive approval by the City Engineer or designee LUC 3.7.2.4.3.

2. A 10' interior landscape border is required along site boundaries of the adjacent residential properties per LUC Table 3.7.2-I.

3. One canopy tree must be provided for every thirty-three (33) linear feet of the interior landscape borders.

4. The planting plan and layout calculations will include both the proper and common name of existing vegetation to remain in place DS 2-07.2.2.A. include the correct names of plant materials.

5. The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape plan.

6. Additional comments may apply.
07/10/2008 ANDREW CONNOR NPPO REVIEW Approved
07/21/2008 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the site drawing to include the rim elevation of the upstream manhole. Where the finished floor elevation is less than 12 inches above the elevation of the next upstream manhole in the public sewer or private sewer collection system, a backwater valve shall be installed in the building drain or branch of the building drain serving that floor Reference City of Tucson Development Standard No. 2-05.0 2.3 and Sections 103.2.3 and Section 710.1, UPC 2006, as amended by the City of Tucson.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/31/2008 VFLORES1 OUT TO CUSTOMER Completed
07/31/2008 SUE REEVES REJECT SHELF Completed