Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T07CM02853
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/05/2007 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 07/05/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Confirm the presence of a return air plenum |
| 07/05/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T07CM02853 7/5/07 1. Address X-Ray Disconnecting Means per NEC 517.72 (B). |
| 07/05/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 07/05/2007 | CHRIS KIEL (WILDAN) | BUILDING-COMMERCIAL | REVIEW | Denied | 1) Please specify the total valuation on the project and specify the total amount to be spent upgrading accessibility in accordance with section 349.6 of the 2003 IBC. Provide a written description of the work to be done upgrading the accessibility. 2) Please provide the required clear floor space on the pull side of the lab door in accordance with 404.2.3 of ANSI 117.1-2003. 3) Please provide safety glazing for the window adjacent to the consult door in accordance with section 2406.3 (#6) of the 2003 IBC. 4) Please provide a vertical grab bar for the water closet in accordance with section 604.5.1 of ANSI 117.1-2003. 5) Please specify on the plans the total building area and most restrictive use in order to verify compliance with chapter 5 of the 2003 IBC. 6) Please revise the typical handicap toilet details to provide compliance with ANSI 117.1-2003 (i.e. clear floor space for the water closet, vertical grab bar, knee and toe clearances, etc.). 7) |
| 07/05/2007 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 07/05/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 07/05/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 07/13/2007 | DROBEY1 | WWM | REVIEW | Needs Review | |
| 07/13/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/13/2007 | DELMA ROBEY | APPROVAL SHELF | Completed |
| 07/13/2007 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 07/13/2007 | DELMA ROBEY | REJECT SHELF | Completed |