Permit Number: T07CM00714
Parcel: Unknown

Review Status: Completed

Review Details: COMMERCIAL-BLDG/FIRE/ZONING/ENG

Permit Number - T07CM00714
Review Name: COMMERCIAL-BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/25/2007 SUE REEVES COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/05/2007 WILLDAN ADA REVIEW Approved
03/07/2007 WILDAN 2ND PARTY REVIEW REVIEW Approved
03/29/2007 DAVID RIVERA ZONING REVIEW Denied 04/02/07

Development Services Department
Zoning Review Section

David Rivera
Principal Planner

Comments:

1. The plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been revised to address the following Zoning review comments.

Truncated domes must be provided along the entire length of the existing pedestrian access aisle between the existing disabled parking spaces and at the existing access ramp.

2. A disabled parking space and access aisle is proposed across from the existing H. C. Parking spaces. The new sidewalk area and access ramps must be provided with truncated domes where the pedestrian area transitions onto the vehicular use area including onto the access aisles. Truncated domes are required at the new access ramp next to the clubhouse.

(Truncated domes are required at all access ramps and at areas where the sidewalk is flush and transitions from the sidewalk to the vehicular use areas. This includes at the H.C. access aisle that transitions from the sidewalk onto the aisle.)

3. Label the maximum slope allowed for handicapped parking spaces and access aisle that serve the parking spaces. The maximum slope allowed per ANSI section 503.4 is 1:48 (2%). Label the slope on the handicapped parking space detail and access aisle.

4. Zoning will re-review the grading plan on the next submittal to ensure compliance with the approved and stamped site plan. Additional comments may be forthcoming.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/02/2007 SUE REEVES OUT TO CUSTOMER Completed
04/02/2007 SUE REEVES REJECT SHELF Completed