Review Details: COMMERCIAL TI

Permit Number - T06CM05246
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/10/2006 EGRANT1 BUILDING-COMMERCIAL REVIEW Needs Review
10/10/2006 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Needs Review
10/10/2006 EGRANT1 WWM REVIEW Needs Review
10/10/2006 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the design of the sanitizing compartment of the 3-compartment sink to be indirectly wasted. It appears that the indirect waste line will be over 15 feet in length, which will require both a trap and an independent vent through the roof.
10/10/2006 DAVE MANN FIRE REVIEW Approved