Permit Number: T06CM05160
Parcel: 133170650

Review Status: Completed

Review Details: SITE

Permit Number - T06CM05160
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/26/2006 STEVE SHIELDS ZONING REVIEW Passed
09/26/2006 STEVE SHIELDS ZONING HC SITE REVIEW Passed
10/18/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied Any project that does not have required landscape plans shall have a landscape mitigation plan prepared to show the disposition of PIP, TOS, and required mitigation, as shown in the summary. Submit a mitigation plan as necessary.
10/18/2006 ANDREW CONNOR NPPO REVIEW Denied Any project that does not have required landscape plans shall have a landscape mitigation plan prepared to show the disposition of PIP, TOS, and required mitigation, as shown in the summary. Submit a mitigation plan as necessary.
10/18/2006 ANY ENGINEERING REVIEW Denied To: Gregor Engineering, Inc. DATE: October 18, 2006
Steve Gregor, P.E.
5232 E. Pima St., Ste. A
Tucson, Arizona 85712

SUBJECT: Temporary Parking Lot, 6627 E. Carondelet Dr.
Site plan T06CM05160 (First Review)
T14S, R15E, Section 07

RESUBMITTAL REQUIRED: Site Plan and Drainage Statement.

The Site Plan (SP) and Drainage Statement (DS) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies of the SP.
2. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10.
3. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11. Dimension all areas of the parking lot to ensure maneuverability.
4. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
5. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14.
6. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
7. Show Site plan number (T06CM05160) on all sheets per D.S. 2-02.2.1.29.
8. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Is the refuse enclosure existing or proposed?
9. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable.
10. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
11. A Stormwater pollution prevention plan (SWPPP) maybe required. Contact Paul P. Machado at 791-5550 x1193.

Drainage Statement:
1. Please include a response letter to the comments along with the corrected copies of the DS.
2. A Drainage Statement is a brief description of drainage conditions applicable for a site which are not affected by 100 year flows of 100 cfs, of more……per S.M.D.D.F.M., chap. II, 2.1.2. The DS must be submitted along with the site plan and accepted with the approval of the grading plan.
3. The content and format of the Drainage Statement should follow S.M.D.D.F.M., chap. II, 2.2.
4. Show the project address or administration address on the cover sheet of the DS

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/6627 E. Carondelet Dr. Site
10/30/2006 CAGUILA1 FIRE REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/30/2006 CINDY AGUILAR OUT TO CUSTOMER Completed