Permit Review Detail
Review Status: Completed
Review Details: REVISION - SITE
Permit Number - T06CM04542
Review Name: REVISION - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/07/2007 | SPOWELL1 | FIRE | REVIEW | Approved | |
| 12/13/2007 | DAVID RIVERA | ZONING HC SITE | REVIEW | Denied | see zoning comments |
| 12/13/2007 | DAVID RIVERA | ZONING | REVIEW | Denied | FROM: David Rivera Principal Planner PROJECT: (Activity Number) T06CM04542 (Address) 667 N 7th Avenue (Use) Charter School TRANSMITTAL DATE: Decewmber 13, 2007 COMMENTS: 1. The plan does not indicate the location of the bicycle parking facilities. Draw and label the location of the bicycle parking facilty. Compliance with development standards 2-09, for location, dimensions, distance from entrance, type of approved facility, number of bicycle the facility supports, security, lighting, physically separated from vehicular use area, etc. must be addressed on the plan. Details if needed to demonstrate compliance must also be added to the plan. 2. Label the slope of the disabled parking spaces and access aisle. Define the accessible route from the disabled parking spaces to the entrance of the building. Indicate where applicable truncated domes and access ramps to comply with ANSI A117.1.406 If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. |
| 12/17/2007 | ANDREW CONNOR | NPPO | REVIEW | Passed | |
| 12/17/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Passed | |
| 12/19/2007 | BIANCA RAMIREZ | ENGINEERING | REVIEW | Approved | DATE: December 19, 2007 SUBJECT: Site Review TO: Manny Delgado LOCATION: 667 N 7th Ave, T14S, R13E, Section 12, Ward 6 REVIEWERS: Bianca Ramirez, CFM ACTIVITY: T07CM04542 (First Review) RESUBMITTAL REQUIRED: Site Plan SUMMARY: Permit T06CM04542 has been reviewed by the Engineering Section and had been issued a PASSED status. Engineering has determined that the site plan was submitted as a condition of Special Exception Land Use Case #SE-07-09. PASSED status has been issured because none of the listed items in the Zoning Examiners Decisions pertain to the Engineering Section. If you have any questions, I can be reached at 837-4928 or Bianca.Ramirez@tucsonaz.gov Bianca C. Ramirez Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4928 office (520) 879-8010 fax |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/04/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 01/04/2008 | SHANAE POWELL | REJECT SHELF | Completed |