Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T06CM02975
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2008 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | Plans that include the approved HDZ information must be provided with submittal under the applicable process per DS 9-01.3.1. Submit two copies of the approved Overlay Zone Plans (Case # T06SA00248) for reference. The application will be reviewed for compliance only when the approved documents are included in the submittal. Additional comments may apply upon subsequent reviews. |
| 06/17/2008 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN REVIEW COMMENTS Date: 6-17-08 Activity: T06CM02975 2nd review Address: 3007 W. Via De Suenos Applicant: Rudy Garcia Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, along with a written response to each of the noted items indicating action taken. SCOPE OF REVIEW: The scope of this plan review includes architectural, electrical, plumbing, mechanical, and energy conservation. The purpose of this review is to verify compliance to the 2006 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Provide two copies of the corrected set of drawings (no clouds or revision numbers please) along with a set of the first submission (cloud corrections on this set please). All corrections and revisions shall be made on original tracings or finished reproducible set. Pen or pencil corrections on final prints will not be acceptable. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets. 2. Any architect and/or engineer involved in the design of the structure shall seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. MECHANICAL PLAN: 3. Provide a mechanical equipment schedule consistent with the information presented, M1302.1. The mechanical plan specifies gas-fired furnaces with an exhaust flue for a gas-fired water heater. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
| 06/23/2008 | HEATHER THRALL | ZONING | REVIEW | Denied | TO: APPLICANT/Development Services, Plans Coordinator/Variance Division/CDRC FROM: Heather Thrall, Senior Planner PROJECT: T06CM02975, 3007 W. Via de Suenos, new residence, SR zoning Site plan, 4th review (T06CM02975) & HDZ review (T06SA00248) TRANSMITTAL DATE: June 23, 2008 COMMENTS: NONE OF LAST REVIEW COMMENTS HAVE BEEN ADDRESSED. Resubmit revised drawings and a response letter, stating how Zoning Review comments were addressed OR resubmit plans with variance paperwork. 1. As a courtesy, zoning reviewed the project for BOTH site plan and Hillside Overlay criteria. The review comments are the same for the last two reviews. 2. The site plan meets all site plan criteria. Once the Hillside Overlay Zone application can be approved, the site plan can be approved by zoning. HILLSIDE DEVELOPMENT ZONE COMMENTS: 3. Per LUC 2.8.1.8.A, the maximum height of a residence in the HDZ is 24'. This height is measured overall from the lowest point of grade at a wall to the roof line. The plans show a height from grade at the garage to the height of the roof at the 2nd story above the garage at 30'4" - not including the parapet wall at the 2nd story, which appears to extend another 3'. The residence is too tall, per diagram in Section 2.8.1.8.A of the Land Use Code. A variance to this section of the LUC must be obtained to allow the residence to be constructed as proposed. 4. This memorandum shall serve as the Official Referral to the Board of Adjustment variance process. Please contact Russlyn Wells at 837-4948 for an appointment to discuss and apply for the variance. 5. Should you obtain a variance, resubmit the plan review package to BOTH the CDRC DIVISION and the PERMIT DIVISION of Development Services - include copies of Board of Adjustment variance paperwork in all sets of the plans. The plans will then be distributed to all reviewers who need to examine the plans. PLEASE NOTE -the plan package can be re-reviewed by staff - but not approved -until AFTER the appeal deadline that will be noted on the final variance memorandum. Plans can be approved AFTER that appeal deadline. If you have zoning questions, please contact me at Heather.Thrall@tucsonzag.gov or at 837-4951. If you have CDRC questions, contact CDRC Manager Patricia Gehlen at 837-4919. C:\planning\cdrc\overlay\T06SA00248 3007 w via de suenos 4.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised overlay and site plan OR additional requested variance documents once a variance is granted. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/25/2008 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 06/25/2008 | SUE REEVES | REJECT SHELF | Completed |