Review Details: SITE

Permit Number - T06CM01793
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/31/2006 MARTIN BROWN FIRE REVIEW Approved
04/11/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Street landscape borders are required, a street landscape border, per Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress.

2. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4

3. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4.

4. A 30" continuous screen along street frontages for vehicle use area must be provided per LUC Table 3.7.2-I

5. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g

6. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.

7. An unpaved planting area, which is a minimum of thirty-four (34) square feet in area and four (4) feet in width, must be provided for each canopy tree. Dimension planter areas on site and landscape plan.

8. Areas where plants are susceptible to injury by vehicular or pedestrian traffic must be protected by appropriate means, such as curbs, bollards, or low walls. Indicate curbing for landscape and natural areas per LUC 3.7.2.3.B

9. Indicate on landscape plan areas of detention/retention, depths of basins, and percentage of side slope. Landscaping is required along retention basin side slopes, bottom and periphery. Plant materials used in basins shall withstand periodic inundation. A minimum of 20 trees per acre must be provided, 33% of tress shall be 24" box or larger. A minimum of 2 shrubs for each tree is required per DS 10.01. Revise landscape plan to include basin(s) treatment.

10. Show on NPP plan the extent of grading boundaries per DS 2-07.2.2.B.4.

11. Additional comments may apply.
04/12/2006 ANDREW CONNOR NPPO REVIEW Denied Show on NPP plan the extent of grading boundaries per DS 2-07.2.2.B.4.
04/28/2006 LOREN MAKUS ENGINEERING REVIEW Denied March 28, 2006
Site Plan Review for T06CM01793
Reviewer: Loren Makus, E.I.T.

The site plan cannot be approved at this time. The following comments must be addressed.

1. A grading permit is required for this project. Submit a complete grading permit application for approval. If more than one acre is disturbed by this project, Stormwater Pollution Prevention Plan will be required with the grading permit submittal.
2. Clearly show drainage patterns including roof drainage on the site plan. (DS 2-02.2.1.A.16)

If you have any questions you may contact me at loren.makus@tucsonaz.gov or at 520.791.5550 ext. 1161.
05/08/2006 PETER MCLAUGHLIN ZONING HC SITE REVIEW Denied See zoning review comments.
05/08/2006 PETER MCLAUGHLIN ZONING REVIEW Denied 1. It is not clear why the 3,700 square foot addition to one of the existing buildings shown on the drawing is not figured into any of the calculations on sheet C0.0. Revise plan by either removing this addition or adding it in to Floor Area, Parking, Allowable Area, Occupancy and all other calculations. DS 2-02.2.2.A.2

2. The pedestrian circulation system must be continuous and provide connections to all buildings, including the new building/addition. Revise plan to show all required sidewalks, fully dimensioned, connecting the buildings to parking areas and adjacent street frontage.
DS 2-08

3. Add a handicap parking calculation to the plan, stating the number of h/c spaces required and provided. All pedestrian sidewalks and ramp surfaces must meet new ADA requirements by utilizing truncated domes rather than scored concrete tactile warning devices. Show the truncated domes indicating any sidewalk grade changes/acces ramps. Also, add a specific general note to sheet 1 indicating that truncated domes shall be used at all crosswalks, access ramps and as otherwise required.
DS 2-02.2.2.A.4,
IBC

4. The loading zone calculation indicates three (3) loading zones are to be provdied but only two (2) are shown on the drawing. Revise. DS 2-02.2.2.A.5

5. Revise bicycle parking calculation to be correct. With a total of 66 vehicle parking spaces provided, a total of 8 percent, five (5) bicycle parking spaces are required. Ten percent, or one (1) space, must be a class 2 bike rack.
LUC 3.3.4

6. Add the existing and proposed use along with the development designator to the notes on sheet C0.0. The commercial storage use in the I-2 zone falls under development designator "35".
DS 2-02.2.1.A.31