Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T06CM00831
Parcel: 10706023G

Review Status: Completed

Review Details: POST 3RD PARTY REVIEW

Permit Number - T06CM00831
Review Name: POST 3RD PARTY REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/24/2006 MARTY DUPONT ADA REVIEW Denied U.S. Department of Justice
Civil Rights Division

Disability Rights Section 950 Pennsylvania Ave, N.W. Washington, DC 20530
E-MAIL AND STANDARD MAIL
Liana Perez, Director
Office of Equal Opportunity Programs and Independent Police Review
City of Tucson
100 North Stone, Sixth Floor
Suite 610
Tucson, AZ 85701
Re: West Side Police Service Center architectural plan review Project Civic Access DJ 204-8-205
Dear Ms. Perez:
We have completed our review of the architectural plans dated January 16, 2006, and January 13, 2006, for the West Side Police Service Center. Our staff architect found the following elements that either did not meet the ADA Standards for Accessible Design or require clarifying information. Please note that this review is based only on what is shown in the drawings provided. If an accessibility issue is not addressed on the drawings, then we have not addressed it in this review. Therefore, it is unclear whether the architect for the project has addressed all relevant accessibility issues.
To facilitate review, I have listed the page number from the plans where the problem was
first noted, then briefly described the problem. The citations within the description are to the ADA Standards for Accessible Design (Standards), 28 C.F.R. pt. 36, App. A, unless otherwise noted.
1. Exterior circulation routes, Drawing C2.2- Detail “D”
No detectable warnings are indicated on the curb ramp. § 4.7.7.
Confirm the slopes of both the primary run and flared sides of the curb ramps provided. §§ 4.7.2, 4.7.5, Fig. 12(a).
West Side Police Service Center
DJ 204-8 -205
2. Meeting room 105 ramp, Drawing A2.1

3. a. There are no details for the ramp indicated in meeting room 105. Please provide
the ramp details, including configuration, dimensions, slope, handrails, and other
relevant elements.
Doors, Drawing A2.2

The following doors have, or appear to have, insufficient side maneuvering clearance in either the push or pull direction. § 4.13.6, Fig. 25:
door 020 door 122
door 124 door 231
door 233
door 306
door 305
No doors are indicated for the rooms listed below. If doors are, in fact, the design intent for any of these locations, and doors are provided, then confirm the door size, maneuvering clearance, and hardware.
“Coffee/Copy” - room 307
“Files” - room 313
“Coffee/Copy” - room 314
Men’s locker room 504 and Flex locker room 511, Drawing A2.3
a. The locker rooms do not include at least one fixed bench 24 inches wide by a minimum of 48 inches long, wall-mounted along the longer dimension. § 4.35.4.
Building signage, Drawing G7.0
a. Sign types “J,” and “Ja” indicate that the sign text is located above the pictogram. Verbal description should be placed directly below the pictogram. § 4.30.4.
Water cooler, Drawing P1.2
a. Confirm provision of the electric water cooler “EWC” indicated in this drawing between Men’s Room 231 and Women’s Room 235, but not indicated in the floor plan drawing A2.2.
Visual alarms, Drawing E2.1
a. No visual alarm is indicated in the following common use areas: Coffee/Copy rooms 307, 314, 404, and 603. § 4.28.1.
Unknown symbol, Drawing E2.3
a. The definition of the electrical symbol which is similar to that of a wall mounted light fixture and containing the letter “A” is not found in the documents. This is presumed to be an element of the assistive listening system. If such is the case, please confirm and specify the equipment.
Project Manual Detail Book
Details 634, 643, 660: Confirm provision of the required clear floor space at the sinks, eye wash stations, and drinking fountains. § 4.24.5.
Confirm that all fire extinguisher cabinets and fire extinguishers are accessible, are mounted within accessible reach ranges, have required clear floor space, and are not subject to the requirements for protruding objects. §§ 4.2.5, 4.2.6, 4.4.1, 4.27.2, 4.27.3, 4.27.4.
Confirm mounting height for all toilet room fixtures, grab bars, mirrors, and other accessories.
General comments
a. No door hardware schedule was found among the submitted documents. Confirm the provision of accessible hardware throughout the facility.
No plumbing fixture schedule was found among the construction documents. Confirm the provision of accessible fixtures and trim throughout the facility.
Confirm that all toilet flush valves will be mounted on the wide, open, or transfer side of toilets. § 4.16.5.
Confirm that all mechanical and electrical controls and devices are accessible, are mounted within accessible reach ranges, and have required clear floor space. §§ 4.2.5, 4.2.6, 4.27.2, 4.27.3, 4.27.4.
If you have any questions, please contact me by phone at (202) 353-3759 or e-mail to Laura.Welp@usdoj.gov. I would be happy to arrange a call with our staff architect if this would be of assistance.
Sincerely yours,
Laura M. Welp, Esq.
Investigator
Disability Rights Section
cc: Alison Colter-Mack
04/25/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied Approved site plan is required prior to building plan approval.
04/25/2006 MARTIN BROWN FIRE REVIEW Approved
04/26/2006 GERRY KOZIOL WWM REVIEW Denied Needs 8th floor credit evaluation. Needs WW/IWC review of trench drain w/oil /sand interceptor- Tom Tomchak 679-5771
05/01/2006 ROBERT SHERRY WATER REVIEW Approved
05/03/2006 PETER MCLAUGHLIN ZONING REVIEW Denied Approved site plan required.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/04/2006 GBONILL1 OUT TO CUSTOMER Completed