| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/06/2006 | WILDAN | 2ND PARTY REVIEW | REVIEW | Denied | January 5, 2005 City of Tucson 270 S. Stone Ave Tucson, AZ 85711 RE: TUCSON POLICE DEPARTMENT MEMORIAL – 1ST REVIEW CITY OF TUCSON LOG NO T05CM06334 WILLDAN PROJECT NO. 13881-5033 The initial review for the above project has been completed. The following items reflect original comments, which remain unaddressed and require a written response indicating any action to be taken. In order to facilitate a shorter back-check time, all corrections and revisions shall be made on the original plans and two new COMPLETE sets of prints shall be returned along with all redline prints. To avoid delays, ensure that all corrections have been made, are complete, and have been coordinated on all applicable detail and note sheets as well as highlighting all changes with appropriate revision number, revision date, and “cloud bubbles”. Pen or pencil corrections on final prints will not be acceptable. Please return comment drawings with your re-submittal. Should you have questions regarding the comments herein, please contact your plans examiner John Stigalt. Occupancy Occup. Load Construction Area S.F. Sprinklered Alarms N/A N/A N/A N/A No No GENERAL COMMENTS: This project has been reviewed for conformance with the 2003 IBC, 1997 UAC, 2000 IMC, 2003 IECC, 2002 NEC codes with local modifications, and the 2003 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan. Please provide a completed special inspection form for the concrete (f’c=3000) and fill placement for fill over 12” in depth at the retaining wall. Reference sections 1704.4,1704.7 and 1704.7.2 IBC. ARCHITECTURAL COMMENTS: See Accessibility Comments STRUCTURAL COMMENTS: Reviewed and accepted PLUMBING COMMENTS: Not part of this review MECHANICAL COMMENTS: Not part of this review ELECTRICAL COMMENTS: Sheet E2 Please provide calculations for all the new and existing exterior light fixtures to show compliance with the City of Tucson Outdoor Lighting Code. Reference the City of Tucson adopted codes. ENERGY CODE COMMENTS: Not part of this review ACCESSIBILITY COMMENTS: Sheet 7 Show on the plans that the new walk and ramp will meet the requirements set forth in sections 403 and 405 of ANSI A117.1-2003. Reference section 106.1.1 IBC. Should you have questions regarding the comments herein, please contact your plans examiner John Stigalt. Sincerely WILLDAN Martin Haeberle, C.B.O. Building Official MAH/cc |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/09/2006 | JMORALE1 | OUT TO CUSTOMER | Completed |
| 01/09/2006 | SUE REEVES | REJECT SHELF | Completed |