Permit Number: T05CM05786
Parcel: 12605146G

Review Status: Completed

Review Details: RESUBMITTAL - SITE ALL

Permit Number - T05CM05786
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/24/2006 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: January 24, 2006
ACTIVITY NUMBER: T05CM05786
PROJECT NAME: First Church of Christ Scientist
PROJECT ADDRESS: 1010 North Alvernon Way
PROJECT REVIEWER: Patricia Gilbert, Engineering Associate

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

RESUBMITTAL REQUIRED: SITE PLAN

SUBMITTALREQUIRED: FLOODPLAIN USE PERMIT APPLICATION, COST ESTIMATE FROM A LICENCED CONTRACTOR


1. Because this project is a change of use a full code compliance review is required. The existing sign will need to be relocated. The sign currently resides within the existing SVT. A clear line of sight between 30" and 6' must be maintained. Revise the sight plan to show the sign in a different location. DS 2-02.2.1.A.10.

The above comment is from the first review. Because the sign is currently located within the SVT, the plan can not be approved until the sign permit is approved. Submit a copy of the sign permit with the next submittal.

2. Submit with the next submittal a Floodplain Use Permit Application.

3. The structure was built in 1973 and is considered to be a nonconforming structure. Improvements to an Existing Nonconforming structure can not exceed 50% of the value of the structure (the full cash value of the structure as shown on the latest assessment rolls of the county assessor). The contractor's estimate (labor and materials) of the improvement to the structure must be submitted. Submit a contractor's estimate for the proposed improvements. Chapter 26.
02/14/2006 ANDREW CONNOR LANDSCAPE REVIEW Denied 1. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1. Variance is needed to wave LUC requirement.

2. Include with re-submittal variance approval documentation. Indicate on the lower right hand corner of the site plan, the variance case number, date of approval, and any conditions imposed.
04/04/2006 MICHAEL ST. PAUL ZONING HC SITE REVIEW Approved
04/04/2006 MICHAEL ST. PAUL ZONING REVIEW Denied CDRC TRANSMITTAL

FROM: Michael St.Paul: Planning Technician


PROJECT:
T05CM05786
1010 North Alvernon Way
Religious Use


TRANSMITTAL: April 4, 2006


COMMENTS: The following comments are for the purpose of applying for a variance before the Board of Adjustment.

1. These comments are also the second review comments for an office conversion to a church in the O-3 Zone. This is a more intense use and requires full code compliance. The Development Designator is "18" Religious Use and the Perimeter Yard Indicator is CC (LUC Sections 2.4.3.2.B.8, 3.2.3.2.A and 3.2.6.4).

2. The minimum distance between the parking area access lane (PAAL) and the covered parking is one foot (1'). The edge or end of the parking space is the beginning or edge of the PAAL. Please revise the parking space to go one foot (1') beyond the edge of the covered parking (DS 2-03.2.1.A.8, DS 3-05.2.2.B.2). The minimum width of the PAAL is twenty-four feet (24'-0") (LUC Section 3.3.7.2) and twenty-three-feet is provided.

3. The maximum lot coverage for Religious Use (Development Designator "18") is seventy percent (70%) in the O-3 Zone. The lot coverage identified on the site plan, Sheet A-2, is seventy-nine point eight percent (79.8%).

4. The minimum number of parking spaces required is thirty-two (32) for the proposed use. The number of parking spaces provided is twenty-four (24).