Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05CM05444
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/28/2005 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/31/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or application for exception per DS 2-15.0. |
| 10/31/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit a separate landscape plan per DS 2-07.0 2. Submit NPPO plan or application for exception per DS 2-15.0. 3. Additional comments may apply. |
| 11/16/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. On the site plan (sheet A-1.1), add a note which states the proposed building height. The building height shall be measured from design grade. (D.S. 2-02.2.1.A.6) 2. If outdoor storage is proposed, delineate the area/s and include the area in the vehicle parking calculation. 3. Gates are noted as being "manually operated". Can the public, solid waste vehicles, and life safety vehicles be able to open the gate. In most cases, DSD staff prefers that gates be left open during business hours to assure access of the aforementioned vehicles and prevent vehicles from stacking into public right-of-way. 4. If applicable, provide a detail of existing and or proposed free standing signage, billboard, and outdoor lighting on the site plan. (D.S. 2-02.2.2.1.A.13) 5. If applicable, all existing and proposed easements must be shown on the plan including width, type, whether they are public or private, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 6. Label the zoning classification of the adjacent properties on the site plan (sheet A1.1). C-2 zoning is located east of the subject property. See cover sheet of redline drawings. (D.S. 2-02.2.1.A.28) 7. On the cover sheet under the Land Use Code information block, revise the proposed use as follows: Principal Use: Construction/Heavy Equipment Wholesaling Secondary Use: General Manufacturing subject to LUC Sec. 2.5.5.4.B.1.a 8. The secondary use "General Manufacturing" is limited to 33% of the gross floor area. To verify compliance with this criteria, label and dimension the manufacturing area on the floor plan and provide the calculation on the cover sheet. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. An appointment is required to discuss these comments in person. |
| 11/17/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Approved | |
| 11/17/2005 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: November 17, 2005 ACTIVITY NUMBER: T05CM05444 PROJECT NAME: Sierra Woodworks PROJECT ADDRESS: 3234 North Palo Verde Avenue PROJECT REVIEWER: Patricia Gilbert, Engineering Associate The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN 1. Add bearings to the lot dimensions. DS 2-02.2.1.A.5. 2. Indicate the scale used for the site plan. DS 2-02.2.1.A.1. 3. Indicate the length of the sight visibility triangles. DS 2-02.2.1.A.10. 4. Palo Verde Avenue north of Fort Lowell Street is not an MS&R Street. Palo Verde Avenue in this area is a local street and does not require future SVTs. Remove the future SVTs from the site plan. DS 2-02.2.1.A.10. 5. It is acknowledged that the site plan references sheet A-0.1 for paving and grading. However part of the required site plan content is drainage patterns. Indicate the direction of drainage on the site plan (drainage arrows). DS 2-02.2.1.A.16. 6. Include on the site plan estimated cut and fill quantities. If cut and fill quantities equal zero, please note on the plan. DS 2-02.2.1.A.17. 7. Sidewalks must be flood free for up to the 10-yr. event. Add a note on the plan, "All roof down spouts on all structures must be routed under any adjacent sidewalk." DS 2-08.4.1.E 8. Indicate if Palo Verde Avenue is public or private, include recordation information (book and page). DS 2-02.2.1.A.18. 9. It is acknowledged that Palo Verde Avenue does not have curb along the street frontage of this property. Keynote 4 indicates a 5' sidewalk along street frontage. Sidewalk is not required since curb is not within the street frontage. The reference in keynote 4 to the 5' sidewalk along street frontage is confusing. Revise the plan to not include the reference to the 5' sidewalk along the street frontage. DS 2-02.2.1.A.21. 10. Handicap curb access ramps are required to be constructed with truncated domes, per recent a Federal ADA requirement. Show a detail or add a general note to the site plan indicating all public and private handicap curb access ramps will have truncated domes. 11. The maximum back up distance for the solid waste collection vehicle is 40'. The proposed location of the solid waste enclosure requires the collection vehicle to back up more than 40'. Revise the site plan to meet this requirement. DS 6-01.4.1.C. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/22/2005 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 11/22/2005 | SUE REEVES | REJECT SHELF | Completed |