Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T05CM05357
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2005 | JIM EGAN | FIRE | REVIEW | Denied | 1. Fire hydrants required. Submit approved water plan. 2. Minimum 20 feet wide, paved, fire access roadway shall be provided and extended to within 150 feet of all portions of the exteror walls of the building. An approved turnaround is required for dead-end access roadways. |
| 11/15/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. The expansion of the building area is greater than 25% previous variances do not apply to proposed expansion, landscaping requirements apply to the entire site per LUC 3.7.1.2.B. 2. Submit separate landscape plan per DS 2-07.0. 3. Street landscape borders shall be a minimum of ten (10) feet wide as measured from the street property line. Dimension landscapes borders accordingly. 4. Landscape borders shall comply with minimum requirements per LUC 3.7.2.4. Fifty (50) percent or more of the area of the street landscape border must be covered with shrubs or vegetative ground cover, 20% shall be 5 gal size or greater, and one canopy tree must be provided for every thirty-three (33) linear feet of the street landscape borders. 5. Provide a 30" continuous screen within landscape borders to screen vehicle use areas per LUC 3.7.2-I. 6. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a 7. Landscaping is required along retention basin side slopes, bottom and periphery. Plant materials used in basins shall withstand periodic inundation. A minimum of 20 trees per acre must be provided, 33% of tress shall be 24" box or larger. A minimum of 2 shrubs for each tree is required per DS 10.01. Revise landscape plan to include basin(s) treatment. 8. The planting plan and layout will include, sizes, and common and scientific name(s) of new and existing vegetation per DS 2-07.2.2.A.1.e 9. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage on the landscape plan per DS 2-07.2.2.2.g. 10. Add note to plan: All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. 11. Include irrigation design and layout per DS 2-06.5.4.A&B 12. Submit NPPO plan or application for exception per DS 2-15.0. 13. Additional comments may apply. |
| 11/16/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit NPPO plan or application for exception per DS 2-15.0. |
| 12/02/2005 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL FROM: Michael St.Paul Planner Technician PROJECT: T05CM05357 3735 North Romero Road Expansion of Manufacturing TRANSMITTAL: December 5, 2005 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The plans submitted are incomplete. The actual site plan appears to be missing, and only particle site plans have been provided. These plans do not have the proper calculations nor do they have the proper shading of the building expansion. Please provide the full site plan. 2. Please provide the last approved site plan. The reference plan provided does not have a zoning approval. It appears to be from the building set. |
| 12/05/2005 | MICHAEL ST. PAUL | ZONING HC SITE | REVIEW | Denied | A full zoning review is required. |
| 12/12/2005 | JOSE ORTIZ | ENGINEERING | REVIEW | Denied | December 14, 2005 ACTIVITY NUMBER: T05CM05357 PROJECT NAME: Storage Room Addition PROJECT ADDRESS: 3735 N. Romero. Rd PROJECT REVIEWER: Jose Ortiz, Civil Engineer Resubmittal required; Drainage Report and if available an Elevation Certificate. In addition to the drainage report a FloodPlain Use Permit is required. Please apply for this permit prior to resubmitting. If you have any questions or would like to meet with me before your next submittal, you may contact me at 791-5640 ext.1191 or Jose.Ortiz@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/30/2006 | AMERY KLAPPERT | OUT TO CUSTOMER | Completed |
| 03/30/2006 | SUE REEVES | REJECT SHELF | Completed |