Permit Number: T05CM02116
Parcel: 11515214B

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T05CM02116
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/11/2005 PATRICIA GILBERT ENGINEERING REVIEW Approved
05/11/2005 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Passed
05/11/2005 CHRISTY FOREMAN BUILDING-COMMERCIAL REVIEW Denied 1)RESTROOM FACILITIES NEED TO BE PROVIDED PER CHAPTER 29 TABLE 2902.1 OR SHOW EXISTING FACILITIES AND THE DISTANCED TRAVELED TO EACH FACILITY.
2) CLARIFY RESTROOM FACILITIES THAT MEET ANSI STANDARDS A117.1 2003 ARE PROVIDED. SHOW REQUIRED CLEAR FLOOR SPACE ENVELOPES.
05/11/2005 ROBERT SHERRY WATER REVIEW Approved
05/11/2005 DAVID RIVERA ZONING REVIEW Approved
05/11/2005 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
05/11/2005 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Denied T05CM02116 DENIED 5/11/05

Since the panel is series rates 22/10, specify that the new 10K rated circuit breakers are rated in series with the 22K.
05/17/2005 CAGUILA1 WWM REVIEW Passed
05/17/2005 CAGUILA1 FIRE REVIEW Needs Review