Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T05CM00872
Parcel: 115062050

Address:
1801 N STONE AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T05CM00872
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/16/2007 MARTIN BROWN FIRE REVIEW Approved
07/19/2007 STEVE SHIELDS ZONING REVIEW Denied Site plan approval required. See site review comments.
07/23/2007 PATRICIA GILBERT ENGINEERING REVIEW Denied Approved site plan is required prior to building plan approval.
08/02/2007 LINDA BUCZYNSKI ELECTRICAL-COMMERCIAL REVIEW Approved
08/07/2007 CHRIS KIEL (WILDAN) BUILDING-COMMERCIAL REVIEW Denied GENERAL: Please revise all code references and details to the codes adopted by the City of Tucson at the time of submittal (i.e. 2003 IBC and ANSI 117.1-2003, etc.).

1) Provide structural calculations and details for light pole bases. COMMENT REMAINS: Please revise the structural calculations to the 2003 IBC (ASCE 7-02) as adopted by the City of Tucson at the time of submittal. In addition, please have the structural engineer of record seal the details associated with his design.

2) Provide structural calculations and details for retaining / site wall. COMMENT REMAINS: The current submittal still has not provided the structural calculations for the retaining/site walls per section 106.1.1 of the 2003 IBC.

3) Accessibility from parking lot into building. COMMENT REMAINS: The current submittal still has not provided sufficient information regarding the accessibility from the parking lot into the building in order to verify compliance with chapter 10 and 11 of the 2003 IBC and ANSI 117.1-2003.

4) Dimension accessible parking and ramps. COMMENT REMAINS: The current submittal still has not provided sufficient information regarding the accessible parking and ramps in order to verify compliance with chapter 10 and 11 of the 2003 IBC and ANSI 117.1-2003. Detail 5/C1.4 has standard dimensioning, but the site plan provides no dimensions.

5) Rise and run of stairs, clarify where handrails and guardrails are required. Provide details. COMMENT REMAINS: The current submittal still has not provided sufficient information in order to verify compliance with chapter 10 of the 2003 IBC (i.e. handrail size, actual rise and run of the stairs, overall elevation difference for the need of guards, etc.).

6) Keynote 11 detail per ANSI a117.1 2003, ramps - slope etc. COMMENT REMAINS: Please coordinate keynote 11 on sheet C1.1 regarding the ramps and the denoted signage per section 106.1.1 of the 2003 IBC. The current submittal for keynote 11 references bicycle parking signage but calls out ramps. In addition, please provide the appropriate ramp details in order to verify compliance with chapters 10 and 11 of the 2003 IBC and ANSI 117.1-2003.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/05/2007 GERARDO BONILLA OUT TO CUSTOMER Completed
09/05/2007 GERARDO BONILLA REJECT SHELF Completed