Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T05CM00872
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/16/2007 | MARTIN BROWN | FIRE | REVIEW | Approved | |
07/19/2007 | STEVE SHIELDS | ZONING | REVIEW | Denied | Site plan approval required. See site review comments. |
07/23/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | Approved site plan is required prior to building plan approval. |
08/02/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
08/07/2007 | CHRIS KIEL (WILDAN) | BUILDING-COMMERCIAL | REVIEW | Denied | GENERAL: Please revise all code references and details to the codes adopted by the City of Tucson at the time of submittal (i.e. 2003 IBC and ANSI 117.1-2003, etc.). 1) Provide structural calculations and details for light pole bases. COMMENT REMAINS: Please revise the structural calculations to the 2003 IBC (ASCE 7-02) as adopted by the City of Tucson at the time of submittal. In addition, please have the structural engineer of record seal the details associated with his design. 2) Provide structural calculations and details for retaining / site wall. COMMENT REMAINS: The current submittal still has not provided the structural calculations for the retaining/site walls per section 106.1.1 of the 2003 IBC. 3) Accessibility from parking lot into building. COMMENT REMAINS: The current submittal still has not provided sufficient information regarding the accessibility from the parking lot into the building in order to verify compliance with chapter 10 and 11 of the 2003 IBC and ANSI 117.1-2003. 4) Dimension accessible parking and ramps. COMMENT REMAINS: The current submittal still has not provided sufficient information regarding the accessible parking and ramps in order to verify compliance with chapter 10 and 11 of the 2003 IBC and ANSI 117.1-2003. Detail 5/C1.4 has standard dimensioning, but the site plan provides no dimensions. 5) Rise and run of stairs, clarify where handrails and guardrails are required. Provide details. COMMENT REMAINS: The current submittal still has not provided sufficient information in order to verify compliance with chapter 10 of the 2003 IBC (i.e. handrail size, actual rise and run of the stairs, overall elevation difference for the need of guards, etc.). 6) Keynote 11 detail per ANSI a117.1 2003, ramps - slope etc. COMMENT REMAINS: Please coordinate keynote 11 on sheet C1.1 regarding the ramps and the denoted signage per section 106.1.1 of the 2003 IBC. The current submittal for keynote 11 references bicycle parking signage but calls out ramps. In addition, please provide the appropriate ramp details in order to verify compliance with chapters 10 and 11 of the 2003 IBC and ANSI 117.1-2003. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
09/05/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
09/05/2007 | GERARDO BONILLA | REJECT SHELF | Completed |