Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T05CM00872
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/26/2006 | SUZANNE BOHNET | ENGINEERING | REVIEW | Denied | 1. The resubmittal did not include the Drainage Report. Please submit the full drainage package. 2. Please add the estimated cut and fill quantities to the Site Plan. 3. The curb access ramps are referenced by the incorrect Keynote. Please revise. 4. Please review all Keynote and Detail descriptions and call-outs. Revise as necessary. 5. Please revise the stem of the sight visibility triangle on Lester to a 20-foot dimension. 6. Please revise the refuse container enclosure per the enclosed handout. Please ensure the spacing allotted for the enclosure is adequate on the Site Plan. 7. Curb access ramps need to be consistent with Standard Detail No. 207, using truncated domes in place of tactile grooves. Please review and revise. Please call to set up a meeting to review these comments at 791-5550 x1188. Thank you. Suzanne Bohnet, CFM Engineering Associate |
| 09/28/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: Wildcat House Site Improvements T05CM00872 Site Plan (2nd Review) TRANSMITTAL DATE: September 29, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Due to the expiration of the requirements of the current Land Use Code and Development Standards will be enforced for this review. Some addition comments have been provided. 2. The subject property is made up of four lots, which must be combined into one. Provide lot combination documents including Assessor's lot combo docs and notarized/recorded covenant. Add the property legal description to the site plan. It appears the lot combo was completed but the recorded information was not provided as stated on your response to comments. Also the provided legal description does not match the Assessors information, see attached. DS 2-02.2.1.A.2 3. The detail provided for the Class 2 bicycle parking does not meet the requirements of D.S. 2-09.0, Supplement 9. The bollard style bike rack does not meet the requirement for a two-point support system. Revise detail to meet this requirement. DS 2-09.2.3, DS 2-09.5.1 4. Keynote 11, "NEW SIGN TO SAY BICYCLE PARKING IN REAR" points to curb access ramps through out the project, please revise. 5. Detail 5/C1.4, revise the hatching to reflect what is shown on the plan and relocate the max. slope so that it is readable. Revised the dimension on the plan to reflect the 11' parking space and the 5' access isle. 6. Detail 2/C1.4, revise the detail to show "TRUNCATED DOMES" in place of the "TACTICAL WARNING DEVICE" per ICC/ANIS A117.1-2003 406.13. 7. Truncated domes are required the full width of the flush surface at the handicapped parking area. ICC/ANIS A117.1-2003 406.13. If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180. C:\planning\site\t05cm00872rs.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 09/28/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Denied | See zoning comments |
| 09/29/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. A street landscape border is an area with a minimum width of ten (10) feet, as measured from the street property or MS&R lines running the full length of the property bounding the site except for points of ingress-egress per LUC 3.7.2.4. All street frontages along N. Stone, N. 9th, W. Lester, and W. Plata for buildings and vehicle use areas require a landscape buffer, Indicate dimensions for borders from MS&R or street property lines. 2. Street landscape border shall be located entirely on site except that, if approved by the City Engineer per LUC 3.7.2.4. Revise keynote #32 on site plan to indicate a 10' landscape border 3. Indicate square footage and calculation of the percentage of vegetative coverage for all landscape areas per DS 2-07.2.2.2.g 4. The planting plan and layout calculations will include the following Information: · Locations, size, and name of existing vegetation to remain in place. · Material and areas of inert ground cover. All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Designate treatment for landscaped areas. 5. Show on landscape plan existing and future sight visibility triangles DS 2-02.2.2.1.A.10 6. Walls constructed in a single continuous line shall extend into a street landscape border no more than the actual width of the fence or wall. Where a fence or wall incorporates offsets or similar design features, a screen may extend a maximum of three (3) feet into the street landscape border per 3.7.3.2.B.3. Move screen walls to the back of street buffers 7. Revise details as necessary on sheet C 1.4 to reflect changes made to landscape border width and screen wall locations per DS 2-07.2.2.D. 8. Within a vehicular use area, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a. Additional trees are required for vehicle use areas. 9. Minimum 25' height clearances for refuse storage collection site must be free of any overhead obstructions (wires, branches, etc) per DS 6-01.4.3.G. Relocate tree as necessary. 10. Additional comments may apply |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/11/2006 | DELMA ROBEY | OUT TO CUSTOMER | Completed |
| 10/11/2006 | SUE REEVES | REJECT SHELF | Completed |