Permit Number - T05CM00693
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/11/2005 | DOUG WILLIAMS | ENGINEERING | REVIEW | Approved | |
| 05/12/2005 | DAN CASTRO | ZONING HC SITE | REVIEW | Approved | |
| 05/12/2005 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 05/17/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C |
| 05/17/2005 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1. Submit a separate landscape plan per DS 2-07.0. To verify that entire site meets current minimum requirements. Indicate all improvements including existing treatment along Airport Wash. 2. A street landscape border, Sec. 3.7.2.4 of the LUC, is a landscape area with a minimum width of ten (10) feet, running the full length of the street property line(s) bounding the site except for points of ingress-egress. On streets designated as Major Streets and Routes (MS&R), the street landscape border is measured from the MS&R right-of-way line as determined by LUC 2.8.3.4. 3. Fifty (50) percent or more of the street landscape border area must have shrubs and vegetative ground cover per LUC 3.7.2.4 4. Indicate square footage of all landscaped areas and calculation of the percentage of vegetative coverage per DS 2-07.2.2.2.g 5. One (1) canopy tree must be provided for every thirty-three (33) linear feet of landscape border per LUC 3.7.2.4 6. A 30" continuous screen along street frontages for vehicle use area must be provided. per LUC Table 3.7.2- 7. Show on site plan existing and future sight visibility triangles DS 2-02.2.2.1.A.10 8. The planting plan and layout calculations will include the following Information: · Both the proper and common name of each type of plant material. · Locations, size, and name of all existing vegetation to remain in place. · Material and areas of inert ground cover. All disturbed areas including adjacent right of ways shall be treated with ground cover such as decomposed granite to help reduce dust pollution per LUC 3.7.2.7. Indicate treatment for landscaped areas. 9. Within vehicular use areas, one (1) canopy tree is required for each 10 motor vehicle parking spaces and every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk) per LUC 3.7.2.3.A.1.a 10. Landscaping along parking lots where plants are susceptible to injury by vehicular traffic must be protected by appropriate means, such as curbs, bollards, or low walls per LUC 3.7.2.3.B 11. Submit Application for Exception; include acceptable documentation, which clearly indicates that the project will not impact Protected Native Plants. Such documentation includes photographs of the site taken from all sides of the property. Photographs of the site are necessary for NPPO approval per DS 2-15.2.0.C 12. Include irrigation system specifications, design, and layout per DS 2-06.5.4.A and 2-06.5.4.B. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/17/2005 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 06/17/2005 | CINDY AGUILAR | REJECT SHELF | Completed |