Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T05BU02323
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/03/2005 | ANDREW CONNOR | NPPO | REVIEW | Denied | Submit stamped approved development plan including landscape plans to continue review. |
| 10/21/2005 | DAVID RIVERA | ZONING | REVIEW | Denied | 10/21/05 Development Services Department Zoning Review Section David Rivera Principal Planner Comments: 1. The grading plan has been reviewed by Zoning Review Section but cannot approve the plan until it has been approved by the Engineering, and Landscape Review Sections and until all zoning comments or concerns have been addressed. 2. Zoning could not verify that the grading plan was in compliance with the approved development plan. Please submit two copies of the approved and stamped development, landscape, and NPPO plans with the next grading plan submittal. 3. Zoning will re-review the grading plan on the next submittal to insure compliance with the approved site/development plan. Additional comments may be forthcoming. 4. A site card with DSD approvals by Fire, Zoning, Handi-cap, Engineering, and Landscape/NPPO including the approved development plan stamped for site plan approval and signatures is required before the grading plan can be approved by Zoning. Two copies of the approved development plan, landscape and NPPO plans are to be submitted with the grading plans packet for processing and approval as a site plan. No fees are involved in re-stamping the development/tentative plat plans as an approved site plan. The development plan may be walked through for stamps and site card sign off. Submit the following: two copies of the stamped development plan, landscape and NPPO plans must be included with the grading plans packet processed together for site approval. |
| 11/04/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Tony Tsang, P.E. DATE: November 4, 2005 A.C. Tsang Engineering Group, Inc. 4626 E. Ft. Lowell Road, Ste. S. Tucson, Arizona 85712 SUBJECT: Rincon Baptist Church, 7500 E. Golf Links Road Grading Plan T05BU02323 (First Review) T14S, R15E, Section 29 RESUBMITTAL REQUIRED: Grading Plan and SWPPP The Grading Plan (GP) and Stormwater Pollution Prevention Plan cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with 3 corrected copies of the GP. 2. The GP cannot be approved prior to the approval of the Development Plan. 3. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. 4. Add note: All Grading shall conform to City of Tucson D.S. 11-0. 5. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting" 6. Add the basin(s) maintenance responsibility note per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the GP. 7. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed. 8. Show details of all surface materials. 9. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 10. Call out all slopes and stabilization material (concrete, riprap, gabbions or vegetation). 11. Slopes of 3H: 1V require hand placed riprap. 12. Slopes of 2H: 1V or greater require grouted riprap. 13. Cut or fill slopes require a 2' minimum setback from property line. 14. Drainage patterns with percent slopes (Show patterns within the first 100 feet from the property line). 15. Flow arrows, grades and flow rates within and adjacent to site to show drainage scheme. 16. Call out peak discharges entering and exiting the site. Drainage report: 1. The DR has been accepted by engineering. Stormwater pollution prevention plan: 1. The SWPPP has been accepted be engineering. Re-submit 2 copies of the SWPPP along with the re-submittal of the GP. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax C:/7500 E. Golf Links Grad |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/08/2005 | GBONILL1 | OUT TO CUSTOMER | Completed |
| 11/08/2005 | SUE REEVES | REJECT SHELF | Completed |