Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM04544
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/03/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 11/04/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | Site Plan 1. Please include a response letter with the next submittal that states how all comments have been addressed. Include plans/redlines from previous plan submittal. 2. A minimum one (1) way traffic aisle is twelve (12) feet in width, unless it also serves as a fire lane, in which case, the minimum width is twenty (20) feet. D.S. 3-05.2.1.C.1&2 Indicate One Way arrows. 3. Indicate a dimensioned detail of the valet stands. 4. Indicate roof slope and location of downspouts. Add note, "All roof spouts will be routed under any adjacent sidewalk." D.S. 2-08.3.1 & 4.1.E 5. Grant Road is MS&R with Future R.O.W. of 120', which intersects with Tucson Blvd. requiring a widening of 150' on Grant Road and 90' on Tucson Blvd. Closed unused driveways. D.S. 2-02.2.1.A.18 6. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. D.S. 2-02.2.1.A.19 |
| 11/09/2004 | PATRICIA GEHLEN | ZONING HC SITE | REVIEW | Denied | see zoning comments |
| 11/09/2004 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Zoning 11/9/2004 The following items must be revised on the site plan. Please include a written response to all comments: 1) A location map must be added (DS 2-02.2.1.A.4), 2) The height of the proposed addition must be added to the site plan notes (existing is not sufficient) (DS 2-02.2.1.A.5), 3) 31 parking spaces could not be located on the site plan. The number of parking spaces required may not be verified until the number of vaccum, wash, and drying bays are listed. Fully dimension the angled parking spaces on the north side of the lot (per the last approved site plan these are not new so change the keynotes. The last approves site plan shows parking in this area). Show all required stacking spaces (DS 2-02.2.1.A.8 and 2-02.2.2.A.4), 4) Dimension distance between new valet stands and all curbing. Stacking lanes must be a minimum of 11 feet wide (DS 3-05.2.1.C.2.b), 5) The existing and future SVT's for the ingress/egress location onto Grant Road must be added to the site plan (because the ingress/egress location has changed since the last approved site plan) (DS 2-02.2.1.A.10), 6) The location of all doorways in the new addition must be added to site plan so pedestrian circulation requirements may be defined (DS 2-02.2.1.A.12), 7) Per the last approved site plan and LUC 3.4.5.3) one (1) 12' by 35' loading zone is required. Revise the site plan and notes as required (DS 2-02.2.1.A.14 DS 2-02.2.2.A.5), 8) Dimension the existing and future 1/2 ROW's for Grant and Tucson Blvd. Please include intersection widening. (DS 2-02.2.1.A.19 & 21), 9) Add the % expansion calculation to the general notes (DS 2-02.2.2.A.6), 10) All easements must be shown on the site plan. Include the location, type, dimensions and recording information (see keynote 16) (DS 2-02.2.1.A.20), 11) If there are indeed 31 parking spaces provided, two (2) handi-cap spaces are required, 12) Please provide continuous pedestrian circulation from the handi-cap space(s) to the front door. |
| 11/15/2004 | Andrew Connor | LANDSCAPE | REVIEW | Denied | Site plan approval is necessary by remaining reviewing agencies to continue review. |
| 11/16/2004 | ANDREW CONNOR | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/22/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 11/22/2004 | SUE REEVES | REJECT SHELF | Completed |