Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T04CM04415
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/09/2008 | SEPTIC APPROVAL | WWM | REVIEW | Approved | |
| 12/13/2007 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 12/14/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 12/17/2007 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 12/17/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 12/17/2007 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 12/20/2007 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE HANDICAP ACCESS FROM STREET TO FACILITY ENTRANCE PER IBC SECTION 1104.1. 2. 1:1 CURB SLOPE INDICATED ON SHEET C-2 AT HANDICAP ACCESS RAMP DETAIL DOES NOT MEET ANSI SECTION 405.2 REQUIREMENT. 3. TOILET INDICATED ON SHEET 3: A) MUST HAVE HIGH/LOW DRINKING FOUNTAIN PER ANSI SECTION 602.4. B) LAVATORY MUST MEET CLEARANCES PER ANSI SECTION 606 AND YOUR SHEET 4. C) SHOWER MUST MEET CLEARANCES PER ANSI SECTION 608 AND YOUR SHEET 4. 4. PLAN SCALES ON SHEET 3 SHOULD BE REFERENCED AS 3/16" RATHER THAN 1/4". 5. SHEET 3 FLOOR PLAN: 1 HOUR FIRE WALL BETWEEN STORAGE AND OFFICE IS A CODE REQUIREMENT, NOT AN ISSUE TO BE VERIFIED. 6. ADDRESS COMMENT 4 OF REVIEW COMMENTS MADE 4/12/05 CONCERNING THRESHOLDS. 7. ADDRESS COMMENT 16 OF REVIEW COMMENTS MADE 4/12/05 CONCERNING MINIMUM 1/8" LETTERING. 8. NEED CALCULATIONS AND APPROPRIATE DETAILS CONCERNING THE TRANSFER OF LATERAL LOADS AT THE ROOF DECK INTO THE EXTERIOR WALL WHEN ROOF TRUSSES ARE PARALLEL TO THE EXTERIOR WALL. 9. ADDRESS COMMENT 23 OF REVIEW COMMENTS MADE 4/12/05 CONCERNING ADEQUACY OF THE EXISTING WALL. NEED CALCULATIONS AND APPROPRIATE DETAILS INDICATING: A) STRUCTURAL ADEQUACY OF EXISTING WALL FOOTING WITH NEW VERTICAL AND LATERAL LOADS (FOOTING SIZE VARIES ON SHEET 2, SECTIONS 2 AND 3. B) STRUCTURAL ADEQUACY OF NEW WALL CONNECTION TO EXISTING WALL. C) VERIFICATION OF EXISTING WALL CONSTRUCTION. |
| 12/21/2007 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 12/27/2007 | HEATHER THRALL | ZONING | REVIEW | Denied | See building code comments and site and grading plan denial comments for ADA issues unresolved. |
| 12/28/2007 | JASON GREEN | ENGINEERING | REVIEW | Denied | A re-review of the site and grading plan is needed to assure ANSI compliance. A sidewalk must connect the street to the building. Resubmit the site plan and grading plan for over the counter approval once the sidewalk has been label and dimensioned. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/10/2008 | VFLORES1 | OUT TO CUSTOMER | Completed |
| 01/10/2008 | SHANAE POWELL | REJECT SHELF | Completed |