Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE ALL
Permit Number - T04CM04415
Review Name: RESUBMITTAL - SITE ALL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/31/2007 | DAVE MANN | FIRE | REVIEW | Approved | |
| 08/03/2007 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 08/13/2007 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | An unpaved planting area, which is a minimum of 34 square feet in area and 4 feet in width, must be provided for each canopy tree. Show planter on the landscape plan for canopy tree within vehicle use area. Note: The site plan and landscape plan must show identical site layout to avoid conflict between the two plans. Ensure that all changes to the site plan are reflected on the landscape & grading plan. |
| 08/13/2007 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 08/13/2007 | HEATHER THRALL | ZONING | REVIEW | Denied | TO: Development Services Department Plans Coordination Office FROM: Heather Thrall, Senior Planner PROJECT: T04CM04415, 2627 E. Benson Hy, Francisco's Honest Concrete Commercial Site Plan, 5th Review TRANSMITTAL DATE: August 13, 2007 COMMENTS: contact me for a counter appointment 1. (Per last review) Proposed building height shall be measured from design grade. Revise all building heights noted on the site plan as required. Add height at design grade to the elevation drawings. (D.S. 2-02.2.1.A.6) The building plans are measured from finished floor at the same heights noted on the site plan that are from grade. The plans need to be fixed to match where the measurements are taken from - which must be from grade. 2. Please dimension building footprint on site plan - to allow building plans to be reviewed accurately. The building plans and the site plan differ in the labeled building footprint area. 3. Depending upon responses provided, further review comments may be forthcoming. I can be reached me at Heather.Thrall@tucsonaz.gov or at 837-4951. HT C:\planning\site plan\T04CM04415 2627 e benson hy 5th.doc |
| 08/13/2007 | HEATHER THRALL | ZONING HC SITE | REVIEW | Approved | |
| 08/30/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: August 30, 2007 SUBJECT: 2627 E Benson Hwy Site Plan and Grading Plan- 5th Engineering Review TO: Francisco H. Maldonado LOCATION: T15S R14E Sec05, Ward 5 REVIEWERS: Jason Green, CFM ACTIVITY: T04CM04415 (site plan) and T06BU00512 (grading plan) SUMMARY: Engineering Division of Development Services Department has received and reviewed the resubmitted site plan (T04CM04415), grading plan (T06BU00512), drainage report (JE Fuller Hydrology and Geomorphology, Inc., June 9, 2006, with addendum dated 14MAY07), and Stormwater Prevention Pollution Plan (SWPPP), for the above referenced property. Engineering Division recommends approval of the site plan and grading plan at this time. ยง If any changes occur to the site plan or grading plan due to other Development Services Departments comments Engineering Division will be required to re-review the submittal and re-stamp the plans approved. If you have any questions, or to schedule an appointment, I can be reached at 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/04/2007 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 09/04/2007 | GERARDO BONILLA | REJECT SHELF | Completed |