Review Details: RESUBMITTAL - SITE
Permit Number - T04CM04073
Review Name: RESUBMITTAL - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2004 | Paul Machado | ENGINEERING | REVIEW | Denied | To: Bruce M. Patton, P.E. DATE: November 3, 2004 Rick Engineering Co. 1745 E. River Road Tucson, Arizona 85718 SUBJECT:3950 E. Paradise Falls Dr., Davidson Elementary Site plan T04CM04073 (Second Review) Grading plan T04BU02233 (Second Review) T13S, R14E, Section 27 NOTE: THE FOLLOWING COMMENTS ARE FROM THE PREVIOUS SUBMITTAL. RESUBMITTAL REQUIRED: Site Plan, Grading Plan, Floodplain Use Permit and Hydrology Report. The Site Plan (SP), Grading Plan (GP), Floodplain Use Permit (FUP) and Hydrology Report (HP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. This parcel is located in the FEMA flood zone "shaded x", "un-shaded x" and the "AE" zone on panel 1643. It is also important to note that school sites may be exempt from the LUC, they are not exempt from the FEMA floodplain requirements. Please submit a Site Plan, Grading Plan, Floodplain Use Permit and Hydrology Report with all the pertinent information contained on each plan. Grading Plan: 1. Please see Site Plan comment. 2. Please include a response letter to the comments along with the corrected copies of the GP. 3. (3) copies of the grading plan and SWPPP are required at submittal. Hydrology Report: 1. Please include a response letter to the comments along with the corrected copies of the HR. 2. A Hec-Ras will be required for an encroachment analysis of the Rillito Creek. 3. A HR is required for parcels affected by 100 year flows of 100 cfs, of more per S.M.D.D.F.M., chap. II, 2.1.2. 4. The content and format of the Hydrology report should follow S.M.D.D.F.M., chap. II, 2.1.3. 5. Please show the project address on the cover of the Hydrology report. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department, 201 N. Stone Avenue, P.O. Box 27210 Tucson, Arizona 85726-7210, (520) 791-5550 x1193 office, (520) 879-8010 fax, C:/3950 E. Paradise Falls Dr. site1 |
| 11/16/2004 | SREEVES1 | LANDFILL | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/02/2004 | SUE REEVES | OUT TO CUSTOMER | Completed |