Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Permit Number - T04CM02883
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2004 | DROBEY1 | BUILDING-RESIDENTIAL | REVIEW | Passed | |
| 07/08/2004 | ASHOFFS1 | WWM | REVIEW | Passed | |
| 07/14/2004 | Andrew Connor | NPPO | REVIEW | Denied | 1. This site is subject to the provisions of: CITY OF TUCSON DEVELOPMENT STANDARD NO. 9-04.0 HILLSIDE DEVELOPMENT SITE IMPROVEMENT including Vegetation preservation and re-vegetation per DS 9-04.3.2. Revise grading note as necessary. 2. Identify the limits of grading and areas of non-disturbance per DS 9-04.3.1.A.2 If natural areas are designated on a site or lot, temporary fencing will be installed where they abut construction areas in order to prevent encroachment into the natural areas. NPP exemption aerial photo approximate clearing limits does not match the grading / septic plan limits of disturbance, include all septic disturbance and utility easements on the site plan. |
| 07/29/2004 | Loren Makus | ENGINEERING | REVIEW | Denied | DATE: July 30, 2004 To: Ray Graffam Owner/Applicant 8731 E. Desert Spring Tucson, Arizona 85730 SUBJECT: 10950 E. Escalante Road Building/Site Plan T04CM02883 (First Review) T14S, R15E, Section 36 RESUBMITTAL REQUIRED: Revised Site Plan The Building/Site Plan cannot be approved as submitted. Please address the following review comments prior to the next submittal. Building/Site Plan: 1. The Plan makes frequent references to Pima County Standards and Agencies. Revise the Plan to be consistent with City of Tucson standards. 2. Include a note indicating the total area of disturbance in square feet. Describe how the areas to remain undisturbed will be protected. 3. Provide an average cross slope (ACS) analysis based on a drawing that is at least 1" equals 50 feet. The contours for the ACS should match the provided contours of the lot as shown on the grading plan. 4. On the site plan or the grading plan show spot elevations for the tops and toes of each slope. 5. Provide a geotechnical evaluation of the fill slope and the construction of the house on it. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov Loren Makus, E.I.T. Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1161 office (520) 879-8010 fax |
| 08/03/2004 | DAVID RIVERA | ZONING | REVIEW | Denied | August 3, 2004 Development Services Department Zoning Review Section David Rivera Senior Planner Comments: 1. The site plan cannot be approved at this time until the Engineering Section has approved the plan for compliance with the HDZ requirements. 2. Draw, dimension, and label the access easment and list the docket and page number. 3. the disturbance or grading area must be revised to include the area around the septic tanks. The disturbance as shown is not accurate. The area to be dug up for the septic tanks and leaching fields will be disturbed more than what is depicted on the plan. Please revise as required. 4. Please re-number the site plan sheets as sheet one and two. Both sheets have information that the Zoning Review Section reviews for compliance. 5. Please address all Engineering Section review comments related to the HDZ and ACS. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/03/2004 | DELMA ROBEY | OUT TO CUSTOMER | Completed |