Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T04CM01767
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/17/2004 | Jim Egan | FIRE | REVIEW | Approved | |
| 06/18/2004 | Robert Sherry | MECHANICAL-COMMERCIAL | REVIEW | Denied | Revise the total amount of ventilation air for AC-2 to comply with the requirements of Section 403.3.2, IMC 2000. |
| 06/18/2004 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Show the location of the water meter on the site plan and coordinate with the plumbing plan. Reference Section 103.2.3, UPC 1994. 2. Comment not addressed. Provide location and sizing information for gutters and downspouts. Reference Appendix D, UPC 1994. Note: drawings from the metal building manufacturer are not acceptable because they are labeled "not for construction". |
| 06/23/2004 | Raul Palma | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 07/08/2004 | Loren Makus | ENGINEERING | REVIEW | Denied | Include a copy of the approved Development Plan/Site Plan. Include estimated cut and fill quantities. |
| 07/13/2004 | Linda Buczynski | ELECTRICAL-COMMERCIAL | REVIEW | Approved | Comment of 7/9/04: Previous review comments have been satisfied and the electrical design is Code-compliant with the exception of the overhead service. Per the City amendments to the Uniform Administrative Code, Section 108, all service conductors shall be installed underground for all new construction in all occupancies and uses. http://www.ci.tucson.az.us/dsd/Codes___Ordinances/Building_Codes/1997_Administrative_Amendments.pdf Application for Waiver of such requirements is currently being processed. 7/13/04: Waiver referenced above approved by Ray Mahuta. |
| 07/16/2004 | EGRANT1 | ZONING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/19/2004 | BETH GRANT | OUT TO CUSTOMER | Completed |