Permit Number: T04CM00297
Parcel: 130151000

Address:
4537 E 24TH ST

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T04CM00297
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/28/2004 GERRY KOZIOL WWM REVIEW Approved
02/12/2004 David Witt BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T04CM00297

2/12/04 4537 E. 24TH ST.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.




FLOOR PLANS:

1. FLOOR PLAN NOTE #3 ; NOTE THAT BATHTUB AND SHOWER ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R307.2

2. NOTE AND SPECIFY THAT SHOWER ENCLOSURES SHALL HAVE A MINIMUM FINISHED INTERIOR OF 1,024 SQUARE INCHES AND SHALL BE CAPABLE OF ENCOMPASSING A MINIMUM 30" CIRCLE PER UPC SEC. 410.0. ALL GLASS ENCLOSURES SHALL BE TEMPERED.

3. IDENTIFY CEILING HEIGHTS IN ALL AREAS ON FLOOR PLAN. IF SLOPED CEILING, NOTE AVERAGE HEIGHT.

STRUCTURAL PLANS:

1. PROVIDE MANUFACTURER'S CALCULATIONS AND DATA FOR PRE-FAB TRUSSES. TRUSS CALCULATIONS MUST BE SIGNED, DATED AND WET-SEALED BY AN ENGINEER WHO IS REGISTERED IN ARIZONA.

2. SPECIFY AND DETAIL ALL OVER FRAMING. IF SOLID SHEATHING IS USED ON THE LOWER TRUSSES, PROVIDE
MINIMUM OPENINGS OF 22" BY 30" FOR ACCESS AND VENTILATION INTO OVER FRAMED AREAS (>30 S.F.). IF
SOLID SHEATHING IS NOT USED ON LOWER TRUSSES, PROVIDE DETAILS FOR BRACING OF TOP CHORD OF
LOWER TRUSSES.

ELEVATIONS:

1. PROVIDE COMPLETE DRAWINGS OF ALL ELEVATIONS. SHOW BUILDING HEIGHTS.

2. INDICATE ALL MATERIALS USED; STUCCO, CONCRETE BLOCK, GLASS BLOCK, ROOFING SYSTEMS, SIDING,
VENEERS, ETC.

3. NOTE AND SPECIFY A COMPLETE ROOFING SYSTEM: ROOFING TYPE, GRADE OF MATERIALS AND METHOD OF
INSTALLATION PER R905.

4. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905).

5. SHOW CALCULATION OF ATTIC VENTILATION AREA IN COMPLIANCE WITH R806.2. NOTE LOCATION OF ALL
VENTS NEEDED TO COMPLY.

SECTIONS - DETAILS - MISC. NOTES:

1. ON STANDARD DETAIL SHEETS, CROSS-OUT ALL DETAILS THAT DO NOT APPLY OR WERE NOT USED.

2. 1 / 2 ; DESCRIBE THE ANCHOR BOLT AND THE SPACING.

3. 1 / 4 ; FIBERGLASS SHINGLES AREN'T PERMITTED ON 3/8:12 ROOFS. THE ROOF SLOPE APPEARS AS 3/8, 4, AND 3:12 THROUGH OUT THE PLANS. PLEASE CLARIFY.

4. FRAMING NOTE #8 ; PLEASE CONSIDER I.R.C. TABLE R602.3(1) IN LIEU OF THE U.B.C. TABLE 25P.

5. PROVIDE A CROSS SECTION OF THE ROOF'S OVER FRAME AND VENTILATION.

6. THE ENERGY INFORMATION ON SHEET 1 APPEARS TO CONFLICT WITH THE PLANS. ARE THE EXTERIOR WALLS R-11, 2X4, OR R-19, 2X6 ?

PLUMBING PLANS:

1. PLUMBING NOTE #2 ; HARD DRAWN TYPE L COPPER WILL HAVE UNNECESSARY SOLDER JOINTS UNDER THE FLOOR. PLEASE CONSIDER SOFT DRAWN TYPE L .

2. ¾" GAS SERVICE LINE FOR 150,000 BTUH @ 60' APPEARS TO BE INADEQUATE PER U.P.C. TABLE 12-3 .

3. PROVIDE SIZE OF EXISTING WATER SERVICE LINE. ¾" APPEARS TO BE INADEQUATE PER U.P.C. TABLE 6-4 .

4. PLEASE NOTE ON THE PLANS THAT THE MAXIMUM DISTANCE OF THE TUB TRAP TO THE VENT IS 5'-0" PER U.P.C. TABLE 10-1 .

ELECTRICAL PLANS:

1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC.

2. PLEASE ADD A VENT FAN IN THE EXISTING BATHROOM IF ONE IS NOT EXISTING. IF IT'S EXISTING PLEASE PUT IT ON THE PLAN AND LABEL IT AS EXISTING.

3. CORRECT THE MATH ERROR IN THE LOAD CALCULATIONS.

4. PROVIDE AN EXTERIOR OUTLET AT GRADE LEVEL LOCATED IN BACK OF THE
DWELLING, PER E3801.7. IS ONE EXISTING? THESE OUTLETS SHALL BE GFI PROTECTED PER E3802.3.

5. PROVIDE A SMOKE DETECTOR IN THE AREA IMMEDIATELY ADJACENT THE BEDROOM; AND PROVIDE SMOKE DETECTORS FOR THE EXISTING SLEEPING AREAS PER R317.1.1 .





IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110


NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/13/2004 DELMA ROBEY OUT TO CUSTOMER Completed