Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T04CM00284
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/23/2004 | Blanca Espino | ENGINEERING | REVIEW | Denied | Site Plan 1. Indicate a location map. D.S. 2-02.2.1.A.4 2. Indicate all existing buildings and structures, including roof slope and location of downspouts. D.S. 2-02.2.1.A.6 Sidewalks shall be flood free for all storm discharges of up to a ten (10) year flood event. Drainage flowing across all pedestrian circulation paths shall be conveyed under the path for up to ten (10) year frequency flood events. All roof spouts will be routed under any adjacent sidewalk using scuppers. Sidewalks must be flood free for up to the ten year event. Indicate roof direction/drainage. Indicate a detailed dimension of roof spout, splash guard and sidewalk scupper. D.S. 2-08.3.1 & 4.1.E 3. Indicate existing and future sight visibility triangles. D.S. 2-02.2.1.A.10 4. If applicable, indicate location, type, size and height of existing and proposed signage. D.S. 2-02.2.1.A.13 5. Delineate current Floodplain limits as per FIRM Panel 1643K, LOMR 02-12-2003. D.S. 2-02.2.1.A.15 6. Indicate drainage patterns and proposed finish grades. Do not obstruct offsite to onsite flows. D.S. 2-02.2.1.A.16 7. Indicate estimated cut and fill quantities on Site Plan. D.S. 2-02.2.1.A.17 8. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. Grant Road and Alvernon Way are both arterial streets with a widening interestion of 150' both directions. Revise and correct. D.S. 2-02.2.1.A.19 9. If applicable, indicate all easements of record to be graphically shown on the plan together with recording docket and page reference. D.S. 2-02.2.1.A.20 10. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21 11. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. Indicate contour intervals. This should be placed together with the north arrow and scale. D.S. 2-02.2.1.A.23 12. Demonstrate vehicle maneuverability fully dimensioned. Please be aware vehicles require 36' inside radius and 50' outside radius. D.S. 6-01.10.Fig.1 |
| 02/17/2004 | Daniel Castro | ZONING | REVIEW | Denied | COMMENTS: (D.S. Development Standards) (L.U.C. Land Use Code) 1. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 2. The proposed site plan shows three (3) separate parcels. The last approved site plan attached to the submitted site and landscape plan drawings show only one (1) parcel. In addition, Pima County Assessors records indicate the shopping center is made up of one (1) parcel with one (1) tax code. If the shopping center is proposed for a land split, the City Of Tucson Development Services Department prior to site plan approval must approve the split. For information regarding the land split process please contact me at the number provided below. (D.S. 2-02.2.1.A.2) (D.S. 2-02.2.1.A.5) 3. The project address listed on the bottom portion of sheet C-1 (3911 E. Grant Road) is different than the address listed on the site review card (3925 E. Grant Road). Please list the correct address on both items. (D.S. 2-02.2.1.A.3) 4. Provide a location map. (D.S. 2-02.2.1.A.4) 5. Provide by note, the existing and proposed building height. (D.S. 2-02.2.1.A.6) 6. Note the maximum height of the drive through canopy and height clearance. (D.S. 2-02.2.1.A.6) 7. Per letter from Walter Tellez (Zoning Administrator) dated February 15, 2000, the 1996 Board of Adjustment variance decision required the Center to provide a total of 491 vehicle parking spaces onsite. The total was compiled by subtracting the 514 parking spaces required for the Center at that time minus the 23 space parking variance granted by the Board. The number of vehicle parking spaces existing and provided for the shopping center do not add up to the 491 spaces required on-site by the Board's 1996 decision. Please revise the site plan to reflect the 491 required vehicle parking spaces. For further information regarding the prior variance case or a possible variance for this project please contact Wayne Bogdan or Russlynn Wells at (520) 791-5550. 8. If new bicycle parking is to be provided, please provide the bicycle parking calculation (existing and proposed) and class type for the entire shopping center. In addition, provide a fully dimensioned detail of the bicycle parking space class type. Refer to D.S. 2-09 for design criteria. (D.S. 2-02.2.1.A.9) (D.S. 2-02.2.2.A.4) 9. The PAAL located in front of the store entrance and the PAAL located near the stop sign at the southern end of the parking lot do not meet the minimum 24 foot width required for two-way travel. Revise as required. (D.S. 2-02.2.1.A.11) (D.S. 3-05.2.1.C.1) 10. If applicable, provide a detail of proposed free standing signage and outdoor lighting on the site plan. (D.S. 2-02.2.2.1.A.13) 11. Provide a note, which states the number of loading spaces required and provided for the overall shopping center. If a new loading zone is to be provided please label and dimension. (D.S. 2-02.2.1.A.14) (D.S. 2-02.2.2.A5) (L.U.C. 3.4.5.3) 12. All existing and proposed easements must be shown on the plan including width, type, and recording docket and page reference. (D.S. 2-02.2.1.A.20) 13. Correctly label the zoning classification of the adjacent properties to the north and east of the site. You may obtain a copy of the zoning map online at: http://www.ci.tucson.az.us/planning/maps/1314/zm131434.dwf 14. The existing zoning of the shopping center is C1 and C-2. Label the existing zoning classifications and boundary. Refer to the zoning map for zoning boundary location. 15. Label and dimension the vehicle stacking spaces in the drive through lane. A minimum of six (6) stacking spaces is required. The length of a stacking space is 18 feet. (D.S. 3-05.2.1.C.2) 16. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 02/18/2004 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 02/19/2004 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | 1) Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval. Submit existing approved landscape plan. 2) Revise tree islands to comply with minimum size requirements per LUC 3.7.2.3.A.1.c , an acceptable solution is indicated in DS 2-06 Figure-5 3) Create water harvesting basins for the parking and tree islands per LUC 3.7.4.3.B |
| 02/19/2004 | ANDREW CONNOR | NPPO | REVIEW | Approved | |
| 02/24/2004 | JIM EGAN | FIRE | REVIEW | Approv-Cond | Separate plan submittal and permits required for underground fire sprinkler piping. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/25/2004 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 02/24/2004 | TAMI ACHONG | REJECT SHELF | Completed |