Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM04472
Review Name: SITE
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/02/2004 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | SITE PLAN TRANSMITTAL TO: Acorn Associates Architecture Ltd. 4400 E. Broadway Blvd. Tucson, AZ 85711 (520) 977-7187 FROM: Peter McLaughlin Senior Planner Development Services Dept. FOR: Patricia Gehlen Principal Planner Development Services Dept. PROJECT: T02CM04472 Solar Industries 6151 S. Tucson Blvd Site Plan Review (2nd review) TRANSMITTAL: January 2, 2004 COMMENTS: The following items must be revised on or added to the site plan: 1. The Assessors Record maps indicate that the project site is made up of two lots. The lots must be combined prior to site plan approval. Provide copies of Assessors tax combo form and recorded covenant. DS 2-02 2. Specify in the development data setback notes that the required MS&R building setback is dimensioned from the back of future curb location. LUC 3.2.6.5 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
01/02/2004 | PETER MCLAUGHLIN | HANDICAP-SITE | REVIEW | Approved | |
01/06/2004 | JOE LINVILLE | NPPO | REVIEW | Approved | |
01/06/2004 | Joseph Linville | LANDSCAPE | REVIEW | Approved | |
12/30/2003 | Loren Makus | ENGINEERING | REVIEW | Denied | SUBJECT: Solar Industries REVIEWER: Loren Makus DATE: 2 January, 2004 ACTIVITY NUMBER: T03CM04472 T15S, R14E, Section 8 SUMMARY: Engineering Division has reviewed the drainage Report, Stormwater Pollution Prevention Plan, Grading and Site Plans. Approval of the Site Plan may not occur prior to drainage report approval, and is not recommended at this time. Address the following comments in your re-submittal: SITE and GRADING PLAN: 1. As previously commented, provide retention/detention basin details with elevations and dimensions fully labelled. The detail should be provided on the grading plan and in the drainage report. 2. The site and grading plans show retention/detention facilities within the right-of-way along Bilby Road. Contact the City of Tucson Department of Transportation Real Estate Division at (520) 791-4181 to obtain a Temporary Revocable Easement for private use of the Right-of-Way. DRAINAGE REPORT 3. Provide retention/detention basin details with elevations and dimensions fully labeled, in the report (SMDDFM, sec. 2.3.1.6 A 4 a, d & e); Please address all of the above comments. Resubmittal shall include a revised site and grading plan, drainage report, and should also include a completed grading permit application, SWPPP's and required accompanying documents. If you have any questions, I can be reached at 791-5550, extension 1161 or lmakus1@ci.tucson.az.us. Loren Makus Engineering Division Development Services Department |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/03/2004 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
01/07/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |