Permit Review Detail
Review Status: Completed
Review Details: REVISION - SITE
Permit Number - T03CM04472
Review Name: REVISION - SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/04/2006 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 08/14/2006 | JOE LINVILLE | NPPO | REVIEW | Denied | Submit the COTapproved landscape and NPP plans. The application will be reviewed for compliance only when the approved documents are included in the submittal. |
| 08/14/2006 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | Submit the COTapproved landscape and NPP plans. The application will be reviewed for compliance only when the approved documents are included in the submittal. |
| 09/26/2006 | STEVE SHIELDS | ZONING | REVIEW | Denied | DSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: SOLAR INDUSTRIES T03CM04472 Site Plan (2nd Review) TRANSMITTAL DATE: October 02, 2006 COMMENTS: Please resubmit revised drawings along with redlines and a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This plan has been reviewed for compliance with development standards 2-02 site content and specifications. Additional review for compliance with development standards, 2-08, 2-09, 3-01, and 3-05 has been made. 2. It appears the MS&R taper has been deleted from this plan. Provide documentation from COT Traffic Engineering, which states that the taper will not be required and that there is no dedication of right-of-way required. D.S. 2-02.2.1.A19. 3. If there is no dedication of right-of-way then there is no MS&R adjustment available for use in the parking calculation. Revise the calculation. D.S. 2-02.2.2.A.4 4. In the north west corner of the proposed parking the, northern most parking space of the parking provided along the west property line, does not provided enough maneuvering area behind the space. Either remove the space or revise the parking to allow vehicles to back out of this space with out the possibility of backing into the parking spaces to the north. D.S. 2-02.2.1.A8. 5. There are numerous details called out on the plan with a reference to sheet C4. C4 was not provided with this set. C4 was provided with the last approved set and detail 2 does not reflect what is shown on the plan. 6. There is new striping called out on the revised plan that was shown as concrete curbing on the last approved plan along the perimeter parking areas, see engineering comments in regards to use of striping instead of curbing. 7. The accessible route shown at the south entrance along Tucson Blvd & the east entrances along Bilby Rd & Ganley Rd where it is shown as a striped area next to the perimeter parking space needs to be a raised concrete sidewalk with an accessible ramp. D.S. 2-08.4.1 8. The detectable warnings (truncated domes) required at all curb access ramps. ICC/ANSI A117.1-2003 Section 406.13. 9. Clarify how the requirements of LUC 2.8.5.5.B.2 are to be met. If you have any questions about this transmittal, please call Steve Shields, (520) 791-5608 ext. 1180. C:\planning\site\t03cm04472.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and additional requested documents |
| 10/02/2006 | STEVE SHIELDS | ZONING HC SITE | REVIEW | Denied | See zoning comments |
| 10/02/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Denied | SUBJECT: Solar Industries REVIEWER: Loren Makus DATE: 4 October, 2006 ACTIVITY NUMBER: T03CM04472 - R T15S, R14E, Section 8 SUMMARY: Engineering Division has reviewed the revised Site Plan. Approval of the Site Plan is not recommended at this time. Address the following comments in your re-submittal: SITE: 1. Include a complete site plan including the future site plan (addressing future right-of-way and intersection widening) as 2. Clearly indicate on the site plan how barriers such as curbs will be provided to prevent motor vehicles from driving into landscape areas and undeveloped areas of the site.. Please address all of the above comments. If you have any questions, I can be reached at 791-5550, extension 1161 or lmakus1@ci.tucson.az.us. Loren Makus Engineering Division Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/13/2006 | GERARDO BONILLA | OUT TO CUSTOMER | Completed |
| 10/13/2006 | SUE REEVES | REJECT SHELF | Completed |