Review Date Reviewer's Name Type of Review Description Status Comments
07/28/2003 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
07/28/2003 GERRY KOZIOL WWM REVIEW Approved
07/28/2003 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved 1. Access and clearance for backflow devices is required. Reference Section 603.2.3. Locating a backflow device above a ceiling will also require a fixed ladder for access to the platform.
2. A carbonator requires a reduced pressure backflow assembly, not a dual check valve with an atmospheric vent (Note H., Plumbing Notes, Sheet P-2). Refernce Section 603.3.12, UPC 1994.
07/28/2003 ROBERT SHERRY WATER REVIEW Approved