Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T03CM02534
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/09/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 06/10/2003 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/16/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide calculations demonstrating adequate ventilation. Reference Section 401, IMC. 2. Provide a Type II hood over all commercial food heat-producing appliances. Reference Section 507.2, IMC 2000. |
| 06/16/2003 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide indirect waste for prep sink. Reference Section 801.2, UPC 1994. 2. Provide calculations showing water supply piping is sized in accordance with Section 610.4, UPC. Include all existing fixtures in the shell building when calculating the total demand and determining pipe sizes 3. Appliances to be directly connected to the water supply system that do not have listed, integral backflow preventers or integral air gaps may require reduced pressure principle backflow preventers. Please submit equipment sheets for determination. Reference Section 603.0, UPC 1994. 4. Termination of the excess pressure relief from the water heater over a service sink is not approved location. Reference Section 608.5, UPC 1994. 5. Floor sinks and floor drains can't be connected to a grease trap. Reference Section 1011.3, UPC 1994. |
| 06/16/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 06/25/2003 | Martin Haeberle | BUILDING-COMMERCIAL | REVIEW | Denied | 1. A 12" maneuvering clearance is required at the women's restroom door. Reference section 404.2.4 ANSI 117.1. Revise plans 2. The fire rated wall specified calls for fire retardant wood and furring channels. Provide detail and specifications per Table 719.1 IBC 3. Provide the through penetration fire-stop system to be used for the fire rated wall penetrations. Reference section 711.4.1.2 IBC 4. Provide a structural analysis for the proposed soffit and glulam beam. Include method of attachment to existing trusses in calculations. |
| 07/03/2003 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/30/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 07/09/2003 | MONICA VALDEZ | REJECT SHELF | Completed |