Review Date Reviewer's Name Type of Review Description Status Comments
05/30/2002 JIM EGAN FIRE REVIEW Approved
05/31/2002 FRANK KALINSKI WATER REVIEW Approved
06/20/2002 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Denied Mechanical 1.Architectural drawings do not reflect M.E.C. Calc's. 2. Provide outside air to the dressing rooms Per Chapter 4 IMC 2000.
06/20/2002 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Denied Plumbing 1. Provide F.F.E. of building,M.H.Rim Elev., waste line size and slope on the site plan. 2. Provide a waste line isometric drawing on the plan. 3. Inclued the RPPB in the water demand calculations. 4. PVC roof drains shall comply with IAPMO IS 8-92. 5. Show all of the plumbing and roof drains on the plumbing plans.
06/25/2002 BOB SUBA ELECTRICAL-COMMERCIAL REVIEW Denied
07/10/2002 PIMA COUNTY BUILDING-COMMERCIAL REVIEW Denied
07/17/2002 GERRY KOZIOL WWM REVIEW Denied
07/17/2002 ANY FLOODPLAIN REVIEW Approved
07/19/2002 PATRICIA GEHLEN ZONING REVIEW Denied Zoning
7/19/2002
Building plans will be reviewed once the structural reviewers have approved the plans

Final Status

Task End Date Reviewer's Name Type of Review Description
07/19/2002 TAMI ACHONG OUT TO CUSTOMER Completed