Permit Number: T02CM01104
Parcel: Unknown

Address:
317 W 23RD ST

Review Status: Completed

Review Details: SITE

Permit Number - T02CM01104
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/28/2002 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan/Grading Plan
1. Roof drainage is not acceptable to flow across sidewalks. Indicate downspouts and splashguards on all existing and proposed buildings and structures. D.S. 2-02.2.1.7

2. Existing and future sight visibility triangles for an arterial street the Far side 125'. D.S. 2-02.2.1.10, D.S.3-01.5.3

3. Indicate dimensioned refuse enclosure detail. Gates are required. This detail is required to be on the Site Plan.

4. Identify with a symbol the diagonal crossed hatch around the perimeter of the buildings.

5. Indicate a detail of the 5' c.m.u. wall with openings. Site plan only.

6. Show a cross section of basin (s). Site plan only.

Drainage Report
1. Recalculate the Stormwater Retention calculation using the 5-year storm runoff coefficients, soil type "D" as per the Stormwater Detention/Retention Manual, Table 3.4
08/28/2002 BLANCA ESPINO FLOODPLAIN REVIEW Denied SEE ENGINEERING FOLDER.
08/28/2002 BLANCA ESPINO SANITATION REVIEW Denied SEE ENGINEERING FOLDER.
08/29/2002 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. City of Tucson lot combination covenant was not found in the resubmittal package.
Previous comment: Pima County Assessors' records indicate this site is comprised of two lots. Lot combination is required prior to site plan approval. Attached is a copy of the lot combination covenant prepared by the City Attorney's office, which must be recorded and a copy submitted to the Zoning Review Section prior to site plan approval.
D.S. 2-02.2.1.A.2

2. If applicable, provide a detail of proposed freestanding signage and outdoor lighting on the site plan.
D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25

3. Label and dimension future sight visibility triangles along 10th Avenue. A vehicle parking space may not be located within a sight visibility triangle.
D.S. 2-02.2.1A.10

4. Note the building area and vehicular use area expansion calculations.
D.S. 2-02.2.2.A.6

5. Indicate the location of the disabled parking sign on the handicap parking space details on sheet C-2.0.

6. A response letter addressing the 1st review comments was not found in the resubmittal package. Please provide a response letter with the resubmittal package.

7. All requested changes must be made to the site and landscape plans.
D.S. 2-07.2.1.A
09/04/2002 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review comment number five (5) dated September 4, 2002.
09/16/2002 JOE LINVILLE LANDSCAPE REVIEW Approved
09/16/2002 JOE LINVILLE NPPO REVIEW Approved
09/17/2002 JIM EGAN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/17/2002 ELAINE ROSE OUT TO CUSTOMER Completed