Plan Number: S20-038
Parcel: Unknown

Review Status: Completed

Review Details: MINOR SUBDIVISION REVIEW

Plan Number - S20-038
Review Name: MINOR SUBDIVISION REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/05/2020 SBEASLE1 START PLANS SUBMITTED Completed
06/05/2020 SBEASLE1 UTILITIES SOUTHWEST GAS Passed
06/05/2020 SBEASLE1 PIMA COUNTY WASTEWATER Reqs Change To Applicant: Please provide an approval document in the next submittal. The Applicant is responsible for obtaining review and approval for wastewater from Pima County (email: Sewer@Pima.gov) prior to Mayor & Council approval of this final plat.
06/05/2020 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change To Applicant: Please provide a Water Availability Letter from Tucson Water (or Ray Water Company, if applicable) in the next resubmittal. Mayor & Council cannot approve until water is assured.
06/05/2020 SBEASLE1 OTHER AGENCIES U. S. POST OFFICE Passed
06/05/2020 SBEASLE1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
06/09/2020 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
06/10/2020 ED ABRIGO PIMA COUNTY ASSESSOR Reqs Change FROM: Ada Griffin, GIS Cartographer
Pima County Assessor's Office

DATE: June 8, 2020

RE: Assessor's Review and Comments Regarding: S20-038 SILVERLAKE INDUSTRIAL PARK SUBDIVISION

___X___ Plat does not meet Assessor's Office requirements.

COMMENTS:

" THE TITLE BLOCK IN THE LOWER RIGHT HAND CORNER LISTS RESUBDIVISION INFORMATION. OUR RECORDS INDICATE THERE IS NO RESUBDIVISION, SO WORDING OF SUCH AND DOCKET AND PAGE INFORMATION SHOULD BE DELETED.

" THERE NEEDS TO BE "GENERAL NOTES". GENERAL NOTES MUST HAVE THE GROSS AREA OF THE SUBDIVISION, THE NUMBER OF LOTS, THE NUMBER OF MILES OF NEW ROAD, PUBLIC AND PRIVATE, EVEN IF THE NUMBER IS 0, AND THE BASIS OF BEARING.

" THE PERIMETER LINE MUST BE SOLID AND HEAVIEST LINE WEIGHT ON THE PLAT. THE LOT LINES AND COMMON AREA LINES MUST BE SOLID AND THE NEXT HEAVIEST. LINES FOR EROSION SETBACKS, FLOODPLAIN LINES ETC. SHOULD BE THE LIGHTEST LINE WEIGHT AND BE DASHED OR DOT-DASHED.

" ALL ADJACENT SUBDIVISIONS SHOULD BE NAMED, WITH MAP AND PLAT IN THE APPROPRIATE AREAS AROUND THE SUBDIVISION. (CURRENTLY WHAT IS SHOWING IS OWNER & PARCEL CODE INFORMATION, HOWEVER IT NEEDS TO BE REPLACED WITH "UNSUBDIVIDED")
07/01/2020 LOREN MAKUS ENGINEERING REVIEW Reqs Change 1. The description of the signer needs to be consistent between the dedication statement and the acknowledgement.
07/01/2020 STEVE SHIELDS ZONING REVIEW Reqs Change CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Section Manager

PROJECT: Silverlake Industrial Park Subdivision
Final Plat (1st Review)
S20-038

TRANSMITTAL DATE: July 1, 2020

DUE DATE: July 6, 2020

COMMENTS: Please resubmit revised drawings along a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-07. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az

This link will take you directly to the section used for the standards review. The UDC & TSM requirements are in the Unified Development Code and can be viewed at the same web link as above

2-07.5.0 CONTENT REQUIREMENTS

1. COMMENT: 2-07.5.1.A.3 - Label all subdivisions within the one-mile area of the location map.

2. COMMENT: 2-07.5.1.D - The "SEQ#________" required in the upper right corners is not visible on sheets 1 & 2 and the "SEQ#________" required in the lower right corners is not visible on sheets 3.

3. COMMENT: 2-07.5.1.H - Provide the subdivision case number, S20-038, in the lower right corner of the plat next to the title block on all sheets.
If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
07/01/2020 SSHIELD1 LANDSCAPE REVIEW Passed
07/06/2020 KAY MARKS PIMA COUNTY ADDRESSING Reqs Change (The Attached PDF mentioned below can be viewed online: www.TucsonAz.gov/Pro. See the Documents section.)

S20-038, Silverlake Industrial Park Final Plat Blocks 1-4, 1st submittal, is being Returned for Corrections by Pima County Addressing. The attached pdf contains Addressing’s comments.

Please let me know if you have any questions. Thank you,

Robin Freiman, Addressing Official

Pima County Development Services Department
(520) 724-7570
07/06/2020 SBEASLE1 UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the final block plat for Silverlake Industrial Park Subdivision, submitted on June 5, 2020. There are existing TEP facilities within the boundaries of the plat. Any costs for relocation or removal of existing facilities will be the responsibility of the developer.

Please call the New Construction Department at 520-918-8300 to apply for service for new development. Submit a final set of approved plans including electrical load and offsite improvement plans to determine how TEP will serve this development. If easements are required for new TEP facilities, they will be obtained by separate instrument.

Please contact me at 520-401-9895 should you have any questions.

Mary Burke, Senior Right of Way Agent

Tucson Electric Power Co.
Office - 520-917-8744
mburke@tep.com
07/06/2020 SBEASLE1 COT NON-DSD PARKS & RECREATION Approved No existing or proposed Tucson Parks and Recreation facilities are affected by this development.

Howard B. Dutt, RLA, Landscape Architect
Tucson Parks and Recreation
(520) 837-8040
07/06/2020 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
07/10/2020 JIM EGAN COT NON-DSD FIRE Completed
07/27/2020 ALEXANDRA HINES ZONING-DECISION LETTER REVIEW Reqs Change July 27, 2020
Grenier Engineering
Attn: Jason Morse
6300 E El Dorado Plaza, Suite A120
Tucosn, AZ 85715

Subject: Final Plat for (S20-038) Silverlake Industrial Park, Lots 1-4

The above referenced project has been conditionally-approved by the City Development Review Committee (CDRC) to prepare for Mayor & Council approval. Please submit five (5) weeks in advance to the next available Mayor & Council meeting, September 9, 2020. Please take the following actions and upload PDF scans of items listed. Once Engineering approves folder in 'Final Plat Package' workflow (5-10 day review), then hand deliver items to 2nd floor lobby drop box for us to obtain City staff's signatures:

1. Address review comments from Zoning, Engineering, Water, Assessor, Addressing, and Wastewater. Provide comment response letter.

2. Original set of executed and notarized (permanent, black ink only) Final Plat on double matte océ or photo mylar. Fill in blank for 'filed at the request of ____'.

3. Title report current within the last thirty (30) days or statement from Title Company certifying the title report previously submitted is still valid.

4. Check or money order made payable to “Pima County Recorder” in the amount of: $24.00 for the first plat sheet and $20.00 for each additional plat sheet (in other words: $20 per plat sheet plus a flat $4.00 handling fee), along with flat $30.00 fee per document for Consent to Dedicate and CC&R (if applicable). The City pays to record the Assurance Agreement. If you are unsure of the fees, please call the County Recorder’s Office at 520-740-4350. Check must be pre-printed with name and address and dated within 45 days of the scheduled Mayor & Council meeting.

5. Original set of executed and notarized CC&R (if applicable).

6. Original set of executed and notarized Assurance Agreement (if applicable). For Third Party Land Trust, provide original Agreement to Construct, original Amendment to Trust, and copy of Trust Agreement.

7. Property owner(s) and consultant mailing addresses to receive notification from the City Clerk’s Office one (1) week prior to and following Mayor & Council meeting.

The Final Plat, CC&R, and Assurance Agreement must be approved at the same Mayor & Council meeting. The City Development Review Committee ensures the Assurance Agreement is reviewed by the City Attorney’s Office prior to the Mayor & Council meeting. The recorded CC&R will be mailed to the address on the cover sheet. The City Clerk’s Office keeps the recorded Final Plat and Assurance Agreement. A copy of the recorded Final Plat and Assurance Agreement will be available on www.tucsonaz.gov/pro.

Should you have any questions, please contact Alexandra Hines at 5208376975 or alexandra.hines@tucsonaz.gov.

xc: Project Record by Activity Number

Final Status

Task End Date Reviewer's Name Type of Review Description
07/27/2020 AHINES2 OUT TO CUSTOMER Completed