Plan Number: S17-027
Parcel: Unknown

Review Status: Completed

Review Details: FINAL PLAT - REVIEW

Plan Number - S17-027
Review Name: FINAL PLAT - REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/14/2017 ARUIZ1 START PLANS SUBMITTED Completed
07/17/2017 ALEXANDRA HINES PIMA COUNTY WASTEWATER Approved July 17, 2017

To: Dan Castro, P.E.
Rick Engineering Company

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

From: _______________________________________________
Debbie Ketchem, Civil Engineer Assistant - Sr.
Development Liaison Unit
Subject: Approval Letter - sewer elements only
Final Plat - 2nd Submittal, P17WS00053 (S17-027)


Pima County Regional Wastewater Reclamation Department (PCRWRD) hereby "Approves" Starr Pass Vistas Village I, Lots 1 - 15 and Common Areas "A" "B", "C", "D-1" & "D-2" as submitted on July 14, 2017. This approval is for elements related to the sewer system only.
Approval will need to be reobtained if the scope of the project changes that may impact the sewer. This also could include the language in the Dedication as well as easements for utilities/sewers. We request the applicant to contact RWRD-DLU to discuss what action if any shall be required. If the jurisdiction requires RWRD signature on the Mylar and there has been changes without communication it could delay the obtaining of RWRD's signature.

Do not hesitate to contact me if you have any questions at (520) 724-6481.

Cc: Lorenzo Hernandez, P.E., C.E. Manager, RWRD
Francisco Galindo, P.E., RWRD
07/25/2017 STEVE SHIELDS ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Steve Shields
Principal Planner

PROJECT: Starr Pass Vistas Village 1
Final Plat (2nd Review)
S17-027

TRANSMITTAL DATE: July 25, 2017

DUE DATE: August 11, 2017

The Zoning Review Section conditionally approves the final plat for this project subject to the following changes. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development package to verify that those changes do not affect any zoning requirements.

1. The final plat cannot be approved until the tentative plat, D17-0117, has been approved.

Once the above comments have been addressed Zoning will provide an over-the-counter review.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised final plat.
08/08/2017 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved Tucson Electric Power Co., (TEP) has reviewed and approves the Final Plat submitted on July 14, 2017. This approval is based on a preliminary electrical placement. Should the design change and additional easements are required, they will be obtained by separate instrument.



If you have any questions, please contact me at 520-917-8744.



Thank you,



Mary Burke

Right of Way Agent III

Tucson Electric Power Co.

Land Resources – RC 131

3950 E. Irvington Road

Tucson, AZ 85714-2114

Office - 520-917-8744

Cell - 520-401-9895

mburke@tep.com
08/10/2017 LOREN MAKUS ENGINEERING REVIEW Approved
09/14/2017 KELLY LEE ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
PLANNING & DEVELOPMENT SERVICES

August 11, 2017

Tri Miller
Rick Engineering

Subject: S17-027 Starr Pass Vistas Village I Final Plat

Dear Tri:

The above referenced project has been CONDITIONALLY APPROVED by the Community Design Review Committee. Please make any necessary corrections and submit the following documents:

1 Executed Final Plat Double Matte Océ or Photo Mylar.

2 Title reports current within the last thirty (30) days.

1 Check made payable to "Pima County Recorder" in the amount of $20.00 per plat page plus a flat $4.00 handling fee, along with Consent to Dedicate and CC&R fees if applicable. Consent to Dedicate and CC&R fees are $10.00 for the first 5 pages and $1.00 for each additional page. If the Consent to Dedicate is also a fixture filing, there is an additional $9.00 fee. If you are unsure of the fees, please call the County Recorders Office at 520-740-4350.

1 Original Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable).

1 Copied Set of Executed and notarized CC&R's document (if applicable) and Assurance Package (if applicable).

1 CD with Digital Copy in PDF Format of Plat, CC&R's (if applicable) and Assurances (if applicable).

1 Provide the property owner(s) and engineering mailing address on a sheet of paper in the submittal to receive proper notification 1 week prior to the Mayor and Council Meeting.

The Planning and Development Services Department makes sure the Assurances (if applicable) are reviewed by the City Attorney's Office prior to being presented to the Mayor and Council. Plats, CC&R's and assurances must be approved at the same Mayor and Council Meeting. Please expect 5 weeks from the date submitted to the date scheduled for Mayor and Council approval.

Should you have any questions, please call me at (520) 837-6999 or Patricia Gehlen at (520) 837-4919.

Sincerely,


Kelly Lee

All comments for this case are available on our website at tucsonaz.gov/PRO.

Via Permits Plus/E-mail

Final Status

Task End Date Reviewer's Name Type of Review Description
09/14/2017 KLEE1 APPROVAL SHELF Completed
09/14/2017 KLEE1 REJECT SHELF Completed
09/14/2017 KLEE1 OUT TO CUSTOMER Completed